Mitel SX-200 Documentation page 147

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

COMMON ALERTING DEVICES (NIGHT BELLS)
.
. . .
Description
This feature allows incoming and internal calls directed to the Atten-
dant Console to appear also at one of three common alerting devices.
The call may be answered either from the Attendant Console, or from
a station with TAFAS Access in its COS. The system provides a contact
closure which is used to operate the alerting device. See TAFAS.
Conditions
None
Programming
Assign 1, 2 or 3 (for common alerting devices 1, 2 or 3, respec-
tively) to Day, Night 1 and Night 2 when programming each
Non-Dial-In Trunk that is to appear on a common alerting de-
vice.
Assign Option Number 54 (TAFAS Access) to the COS of any
extension which is to answer calls appearing on common alert-
ing devices.
In consoleless operation, it is desirable to have a minor alarm
ring Night Bell 3. Select System Option 162 (Night Bell 3 with
Minor Alarm Enable).
Operation
In consoleless operation, the night bell may be turned off by
l
dialing 555 + 1 from the console or test line, or by pressing the
ALARM RESET button on the console.
SECTION MiTL9105/9110-096-105-NA