Mitel SX-200 Documentation page 274

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

RANGE
PROGRAMMING
Description
This feature allows Range Programming of extensions in blocks in the
SX-100 or SX-200 system. By entering a range of equipment numbers,
one may assign extension numbers, busy lamp numbers, toil deny
status, a Class of Service, or a pickup group to a selected range of
equipment numbers. The start extension number, busy lamp number
COS number or pickup group number is supplied. The extensions and
busy lamps are assigned sequentially starting at the entered value, and
the COS number, pickup group and toll denial are assigned to the
entire group. As in regular extension programming, any or all of the
extension attributes may be assigned at once, terminating with the
ENTER key. All the usual defaults for extensions (such as COS #l)
apply in Range Programming as well.
Conditions
Extension numbers in each range must be in numerical ascend-
l
ing sequence, with each being of the same digit length; e.g., the
sequence cannot contain ----, 999,1000,
Characters * and # cannot be digits in any of the sequence
l
numbers.
Programming
System Option 212 (Range Programming Enable) m&t be set.
l
See Section MITL9705/91
l
for full details of programming.
Operation
N o n e
SECTION MITL91 OS/91
System Programming
10-096-l OS-NA
Page 219