Mitel SX-200 Documentation page 485

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

SECTION 9105/911
Page 46
11.05
Overload. The change in attenuation when the level of a 1004
Hz signal is increased from 0 to +lO dBm shall not exceed 0.2
11.06
Return Loss. The Return Loss parameters are greater than:
Line-to-Trunk Structural Return Loss
ERL 20 dB
SRL 14 dB
Measured on the trunk side (without pad)
600 ohms + 2.15 &IF.
Trunk-to-Trunk Return Loss (Terminal Balance)
ERL 24 dB
SRL 14 dB
Measured with 900 ohms + 2.15 BF termination.
Trunk-to-Trunk Return Loss (Through Balance)
ERL 27 dB
SRL 20 dB
Measure with respect to 900 ohms + 2.15 PF termination.
Line-to-Trunk nontalking condition
SRL 5 dB
With respect to 900 ohms + 2.15 @F reference.
Trunk-to-Trunk
SRL 10 dB
With respect to 900 ohms + 2.15 LLF reference.
Longitudinal Balance. All connections meet the following re-
11.07
quirements with respect to Longitudinal Balance:
Minimum
H
200
z
65 dB
11.08
Crosstalk Attenuation. The crosstalk attenuation, or coupling
loss, between any two transmission paths is as stated below.
Both paths are terminated in 600 or 900 ohms as required at each end.
The frequency band which applies is 200 to 3400 Hz.
Line-to-Line
-75 dB minimum
Line-to-Trunk
-75 dB minimum
Trunk-to-Trunk
-75
The level of the disturbing signal is 0 dBm.
nontalking
condition
1000 Hz
3000 Hz
60 dB
54 dB
minimum
and
termination in