SECTION MITL91 OS/91
MESSAGE REGISTER AUDIT
.
Page 182
10-096-l OS-NA
Description
This feature allows the Attendant to request a printed list of all exten-
sions that have made local calls, and the total number of call units
made from each extension. The printout format includes date, time,
extension number and the Message Register value for each extension.
Conditions
The printer must be compatible with the requirement for an
l
RS-232 port, with a data speed of 300 or 1200 baud and a
minimum of 80 characters per line.
The request will be ignored if the printer queue is full.
l
The second digit of the trunk group type must be 2 or 4.
l
Assign an access code to Feature Number 18 (Attendant Func-
l
tion) usually as indicated under Operation.
Programming
Select System Option 316 (Room Message Register Audit En-
l
able).
Select System Option 318 (Zero Message Register after Room
l
Register Audit) if the message register is to be cleared after its
contents have been printed.
Operation
Dial ~16.
l
Press the RELEASE button - the display clears and the report is
l
printed (listing is in equipment number sequence).