Make Interval (ms)
Interdigit Time (ms)
10. SIGNALING AND SUPERVISION
TABLE 10-l
DIAL PULSE LIMITS
General
This Part details the technical parameters of the PBX with re-
10.01
gards to signaling and supervisory condition.
Dial Pulse and DTMF Tone Data
10.02 The PBX is capable of accepting and repeating signals from
telephone sets which have the parameters shown in Table 10-1,
Dial Pulse Limits, and Table 10-2, DTMF Tone Limits.
10.03 When any of the frequencies shown in Table 10-2 are present
at the system input, any other single frequency (200-3400 Hz)
should be a minimum of 40 dB below the former. However, DTMF
pulses are registered, in the presence of precise dial tone at a level of
-10 dBm.
10.04 The PBX gives the following signaling conditions:
Dial Pulse Conditions:
l
Pulse Rate
Break Interval
Interdigit Time
DTMF Dialing Conditions:
l
Frequency Deviation
Tone Duration
Interdigit Time
Level, Low Group
Level, High Group
Level, DTMF Signal
Level, Third Frequency Greater than 40 dB below DTMF signal
Twist
Supervisory
Data
10.05 The PBX is capable of responding to or providing the following
supervisory
conditions:
The PBX responds to hookswitch flashes with a duration of
l
between 200 ms and a programmable maximum time (0.7, 0.9,
SECTION 91 OS/91 1 O-096-180-NA
Min.
8.0
50.0
41.7
16.7
300.0
10 s (trunks); 15 s (lines)
9 to 11 pps
58 to 62 percent
800 ms
1 percent
Greater than 40 ms
Greater than 40 ms
Greater than -10 dBm
Greater than -8 dBm
Less than +2 dB
Less than 4 dB.
Max.
12.0
80.0
100.0
62.5
Page 43