Mitel SX-200 Documentation page 709

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

SECTION
MITL9105/911
O-096-500-NA
cabinet,
but
are packaged
into
a shelf
that
forms
a pedestal
for the
[
SX-100
system.
SX-100
Equipment
Cabinet
2.09
The door
on the front
of the SX-100
cabinet
provides
access
to
the
system
maintenance
panel
and
the
printed
circuit
cards
(Figure
2-2). The removable
rear panel
provides
access
to the
system
power
supply,
and the line and trunk
connections.
Cable
entry
to the
equipment
cabinet
is provided
through
a cable
duct
in the rear of the
cabinet.
The
maintenance
panel,
mounted
at the
top
of the
cabinet,
provides
access
to the system
from
the maintenance
console
through
a 50-pin
connector.
To the left of the maintenance
plug is the
master
power
fail transfer
switch,
five power
fail transfer
control
switches
and
the system
POWER ON/OFF
switch.
In addition,
a test
line is provided
which
allows
service
personnel
to access
individual
lines and
trunks.
Mounted
directly
below
the
maintenance
panel
is the equipment
shelf.
This shelf contains
the system
common
control
cards,
plus a number
of trunk,
line and receiver
cards. The optional
reserve
power
supply
is
contained
in a separate
unit that the equipment
cabinet
may sit on.
SX-200
Equipment
Cabinet
2.10
The door
on the front
of the
cabinet
provides
access
to the
system
maintenance
panel,
printed
circuit
cards
and
reserve
battery
supply
shelf
(Figure
Z-3).
The
hinged
rear
panels
hold
the
system
power
supply,
and
provide
access
to the
line and trunk
con-
nections,
and the reserve
power
controls.
Cable entry
to the equipment
cabinet
is provided
through
cable ducts
on either
side of the cabinet.
2.11
The
equipment
cabinet
holds
the
maintenance
panel,
a maxi-
mum
of two
equipment
shelves,
the
optional
reserve
battery
supply
and the primary
power
supply.
The maintenance
panel,
mounted
at the
top
of the
cabinet,
provides
access
to the
system
from
the
maintenance
console
through
a 50-pin
connector.
To the
left
of the
maintenance
plug
is the master
power
fail transfer
switch,
five
power
fail transfer
control
switches
and the system
POWER ON/OFF switch.
In
addition,
a test
line
is provided
which
allows
service
personnel
to
access
individual
lines and trunks.
Mounted
directly
below
the
main-
tenance
panel
is equipment
shelf
2. This shelf
holds
line and/or
trunk
cards.
Below
equipment
shelf
2 is equipment
shelf
1. This shelf
con-
tains
the
system
common
control
plus
a number
of trunk,
line, and
receiver
cards.
The
optional
reserve
power
supply
is contained
in a
completely
enclosed
shelf
located
at the
bottom
of the
cabinet.
All
connections
between
shelves
and
external
equipment
are
made
by
connectorized
cables
from
the rear of each
shelf.
The system
primary
power
supply,
held
on the
lower
hinged
back
panel
of the
cabinet,
converts
the
commercial
input
power
to the
required
system
voltage
levels.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx-100

Table of Contents