Mitel SX-200 Documentation page 712

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

SECTION
MITL9105/911
O-096-500-NA
Maintenance
Panel
2.12
The
plug
on the
right
of the
maintenance
panel
permits
the
service
perscnnel
to pet-form
maintenance
tasks
and enter
new,
or modify
existing
customer
data using
the
maintenance
console.
The
test
line terminals
GI
the
panel
allow
the use of a standard
hand-test
set (butt-in)
to
establish
calls through
the system
using
preselected
circuits.
Equipment
Shehres
2.13
The equipment
shetves
used
in the
SX-100
and
SX-200
sys-
tems
are identical,
and hold up to 21 printed
circuit
cards which
plug
into
the
shetf
backplane.
On the
rear
of the
backplane
are
a
number
of
25-pair
plugs
providing
interconnections
between
the
shelves
and externai
equipment.
In addition
to the plugs
are a number
of screw-down
terminals
allowing
shelf
connection
to the
primary
power
supply
unit
The equipment
shelves
(Figure
2-4)
measure
273
mm (10.75 in.) high, 480 mm (19 in.) wide,
415 mm (16.37 in.) deep
and
weigh
approximately
12.2 kg (27 lb) fully equipped.
Printed
Circuit
Cards
t
2.14
All circuit
cards (Figure
2-5)
used
in the PABXs are identical
in
construction
and
consist
of
a fiberglass
board
with
printed
wiring
patterns
on both
of its faces.
Riveted
to the front
of each board
is a transparent
faceplate
which
allows
the LEDs mounted
on the front
of the
boards
to be easily
seen. The two
color-coded
card extractors,
located
at the
top
and
bottom
of the
faceplate,
identify
the
card
position
within
a shelf and
ensure
that
the card
is seated
correctly
in
the backplane
connector.
Primary
Power
Supply
2.15
The system
primary
power
supply
(Figures
2-6
and 2-7),
pro-
vides
all system
power
from
a 115 Vat.
In the SX-200
system,
optional
factory
strapping
allows
for
220 Vat
operation.
The
SX-100
system
has a 220 Vat adapter
to allow
115 Vat power
to the system.
Electrical
Characteristics
2.16
The electrical
characteristics
of the SX-lOO/SX-200
system
are
listed in Section
MlTL9 105/9 110-096-l
80-NA.
2.17
Both PABXs ore designed
to operate
from
a 48 Vdc source.
A 48
Vdc power
supply
operating
from
commercial
power
is standard
equipment
The
systems
may
be optionally
equipped
with
a charger
and battery
arrangement
which
provides
a minimum
of 2 hours
reserve
power
in the event
of commercial
power
failure.
2.18
In the event
of a power
failure
with
no reserve
power
available,
up to six SX-100
or 12 SX-200
Central
Office
(CO) trunks
can
be arranged
to be automatically
connected
to preselected
extensions.