PAGING ACCESS (EXTENSIONS)
Description
An extension equipped with this feature is permitted access to the
system paging equipment by dialing the required access code. Access
may be restricted to Zone 1 only, Zone 2 only, or to both Zones 1 and
2, depending upon the access code dialed. If an extension tries to
access busy paging equipment, busy tone is returned.
Conditions
A maximum of two paging circuits are provided.
Camp-On or Automatic Callback - Busy may not be activated on
busy paging equipment.
Any extension paging announcement may be overridden by the
Attendant.
Paging amplifiers and loudspeakers are customer-provided
equipment.
A dry relay control is provided for amplifier control purposes for
each zone. (See MITL9105/9
ing and Installation.)
If the Attendant overrides an extension, the extension will re-
ceive busy tone.
Programming
Option Number 53 (Paging Access) must be included in the COS
l
of the extension.
Assign an access code to the paging access required:
l
Pager 2 - Feature Number 11
Pagers 1 and 2 - Feature Number 13.
Operation
Dial the required paging access code - after the short pulse of
l
tone is heard, you are connected to the paging system and may
make the required announcement.