Mitel SX-200 Documentation page 749

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

SECTION
MITL9105/911
O-096-50O-NA
.
Loading
Specific
Data Blocks
(
5.17
1.
SET THE THUMBWHEEL
SWITCHES
ON THE TONE
CONTROL
CARD TO 3282.
2.
FROM THE CONSOLE
OR TEST LINE, DIAL 555 + 72 AND THE
FIRST DATA BLOCK NUMBER
FOLLOWED
BY A* AND THE NEXT
DATA BLOCK NUMBER
OR ANOTHER
* TO SIGNIFY THE LAST
DATA
BLOCK (e.g., to load data blocks 3 and 4, dial 555723*4**).
If busy tone
is heard,
the
port is in use. If the port is idle, dial
tone will be heard.
Note:
At this point, the data part is suspended
and all data will be lost
until it is restored
by resetting
the system
manually
or as part
of a data load. LED 3 does not light.
3.
DISCONNECT
ANY
DEVICE
CURRENTLY
CONNECTED
TO THE
RS-232
PORT (5302).
4.
CONNECT THE RECORDING
DEVICE TO J302 AND ENSURE THAT
THE BAUD RATE SWITCH ON THE SCANNER
IS SET CORRECTLY.
5.
PRESS THE AUTOLOAD
BlJlTON
ON THE IPC. When the autoload
button
is pressed,
the
system
will
reset.
All calls
will
be
dropped
and the
system
will be in power
fail transfer
for the
duration
of the load. The Scanner
card display
will show AA and
all LEDs on the IPC card will light.
6.
ENABLE THE WRITE FEATURE ON THE RECORDING
DEVICE. The
system
will now
load. The LEDs on the Scanner
Card will count
*&rough
numbers
from
01 to 99 as the
data
is being
loaded.
Each time
the count
jumps
back to 01 from
a number
less than
99, this
indicates
that
a new data block is being
loaded.
(Note:
Data Block 1 actually
consists
of two blocks
of data.) WHEN THE
LOAD IS COMPLETE, THE SYSTEM WILL RESET, LEDs on the IPC
Card will extinguish
and the clock will read 0O:OO flashing.
7.
DISCONNECT
THE RECORDER.
8.
RECONNECT ANY DEVICE DISCONNECTED
IN STEP 2.
9.
SET ME
TIME (*5HHMM
Release)
AND THE DATE ("ISMMDDW
Release)
from the console.
(Note:
W is the 2-digit
representa-
tion of the year.)
Note:
PRINTED COPY OF DATABASE.
If a printer
is available
and Sys-
tem Option
259 is enabled,
a printed
copy
of the database
may
be obtained
as follows:
1.
ENSURE THAT THE PRINTER IS CONNECTED
TO 5302 AND THE
BAUD RATE SWITCH IS CORRECTLY
SET.
2.
DIAL 5559
(N) FROM EITHER THE CONSOLE
OR TEST LINE. In
both cases, the printing
starts
immediately
after the last digit is
dialed. N is defined
as follows:
0
A complete
print
1
System
Options,
Feature
Access
Codes,
Classes
of
Service,
Hunt Groups
and Extensions
(Regular)
2
Trunk
and Trunk
Group
Data
:"