SECTION 91 OS/91 1 O-096-180-NA
TABLE
5-l
SYSTEM FEATURE LIMITATIONS
Maximum number of simultaneous calls = 31.
Maximum number of speech paths used by any call = 2
Maximum number of simultaneous consultations = 15.
Maximum number of simultaneous add-on (3-way) calls = 30.
Maximum number of simultaneous station-controlled conference calls = 30.
Maximum number of calls that can simultaneously be camped on to an extension,
or Hunt Group = 30.
Maximum number of simultaneous callbacks that can be enabled = 32.
Maximum number of simultaneous call forwards that can be enabled = 208 (SX-200): 112
(SX-100).
Maximum number of simultaneous "Dial 0" calls = 31.
Maximum number of hunting groups = 12.
Maximum number of calls that can be simultaneously connected to Music on Hold = 31.
Maximum number of stations in a Station Hunting Group = 208 (SX-200); 112 (SX-lct3).
Maximum number of stations in a Call Pickup Group = 208 (SX-200); 112 (SX-100).
Maximum number of dial call Pickup Groups = 30.
Maximum number of trunks assignable to night stations = 100 (SX-200); 52 (SX-100;.
Maximum number of trunks in a Trunk Group = 104 (SX-200); 56 (SX-100).
Maximum number of Trunk Groups = 12.
Maximum number of tails that can override a given extension = 1.
Maximum number of calls that can be simultaneously parked = 31.
Maximum number of simultaneous meet-me conferences = 1.
Maximum number of simultaneous attendant-controlled conferences
Maximum number of calls that can be simultaneously held by one attendant = 4.
Maximum number of simultaneous incoming calls that can be separately identified
attendant = 6 (Recall, Dial 0, LDN 1 through LDN 4).
Maximum number of LDNs that can be identified at the Attendant Console = 4.
Maximum number of simultaneously ringing wake-ups = 10.
Maximum number of speed call tables = 25.
Maximum number of personal Speed Call Tables = 25.
Maximum number of common Speed Call Tables = 18.
Numbering schemes may be l-, 2-, 3- or 4-digit or a combination of one, two, three and four
digits, as long as there are no conflicts in the first digits.
Maximum number of trunk buffers for SMDR = 45.
Maximum number of speed call digits that may be stored = 56 (per table).
Maximum number of SUPERSET sets = 64.
Maximum loop limit for the SUPERSET sets with 26 gauge wire = 2400 feet
Maximum loop limit for the SUPERSET sets with 24 gauge wire = 3400 feet
Maximum loop limit for the SUPERSET sets with 22 gauge wire = 4800 feet