SECTION
MITL9105/911
O-096-500-NA
l
Six power
fail transfer
trunks
(SX-100)
l
Twelve
power
fail transfer
trunks
(SX-200)
a
Optional
reserve
power
supply
0
The SUPERSET 4 Set
l
The SUPERSET 3 Set.
2.02
Maximum
Line and Trunk
Configuration.
The SX-100
and SX-
200 systems
each
consist
of a single
cabinet
(containing
the
switching
circuitry
and the
system
power
supplies)
and
a cordless
desk-type
Supervisor
console
equipped
with
pushbutton
dialpad
and
control
keys. Connections
between
the equipment
cabinet,
the console
and the distribution
frame
are made
using
connectorized
25-pair
ca-
bles.
2.03
Noiseless
operation,
exceptionally
small size and environmental
tolerance
allow
a wide choice
of locations
for the equipment.
Maintenance
(. .1-
2.04
The modular
design
and functional
packaging
of the systems
permit
rapid
location
and replacement
of defective
equipment.
Circuit
malfunctions
are detected
by diagnostic
routines
automatically
initiated
by the CPU. These
diagnostic
routines
are detailed
in Section
MITL9105/9
11 O-096-350-NA.
The
use
of
MITEL
Action
Procedures
(MAPS) helps to locate
the defective
circuit
card or assembly,
in order
to indicate
to the service
personnel
the required
field-replaceable
unit.
Diagnostic
routines
and maintenance
procedures
do not interfere
with
users
not
affected
by the
malfunction.
Because
the system
employs
only electronic
circuits,
preventative
maintenance
is not required.
2.05
System
expansion
is achieved
by the addition
of plug-in
line
and trunk
printed
circuit
cards. Lines are added-in
increments
of
eight,
CO trunks
are added
in increments
of four and special
trunks
are
added
in increments
of two.
Physical
Description
2.06
The
SX-100
and SX-200
systems'
equipment
cabinets
are of
metal
construction,
and are shown
in Figures
2-2 and 2-3.
2.07
All connections
from
the
cross-connecting
terminals
to
the
system
equipment
cabinet
are made
using
connectorized
ca-
bles.
Connections
between
the
cross-connecting
terminals,
the
Su-
pervisor
console
and external
equipment
are made in accordance
with
accepted
practice.
2.08
A reserve
power
supply
and battery
charging
system
are avail-
able
as an option.
The
reserve
power
supply
is designed
to
maintain
system
operation
for a minimum
of 2 hours
in the event
of a
primary
power
failure.
These
items
can be mounted
within
the SX-200
Page 3