CANNOT DIAL A TRUNK AFTER FLASHING
Description
These options inhibit an extension from accessing a trunk after flash-
ing the switchhook The System Option applies the restriction to all
extensions; if only certain extensions are to be restricted, the exten-
sion COS must include the relevant COS option.
Conditions
If the user has a trunk on "Consultation Hold", the "Cannot Dial a
l
Trunk After Flashing" and "Cannot Dial a Trunk After Flashing if
Holding or in a Conference with a Trunk" options apply.
This option does not apply to extensions with Option Number 48
l
(Broker's Call) in their COS.
Programming
Select System Option 183 (Cannot Dial a Trunk After Flashing)
l
for systemwide restriction, or select COS Option 94 (Cannot Dial
a Trunk After Flashing) for each extension to be restricted.
Operation
None