5.12
The following restrictions are desired for each user group with
each Trunk Group:
Trunk Groups 1 and 2 (local CO):
l
User A:
User B:
User C:
Trunk Group 3 (tie):
User A:
User B:
User C:
First, it can be seen that no digit absorbs will be required. Therefore,
no Absorb Plans need be defined or assigned to any Trunk Groups.
This is shown in Figure 5-4.
TRUNK
G R O U P
NO
ABSORB
PLAN
APPLIES
CONTROL
CONTROL
C O N T R O L
PLAN
PLAN
NOTE: CLASS OF RESTRICTION 1 = GROUP "B" USERS
CLASS OF RESTRICTION 2 = GROUP "C" USERS
Figure 5-4 Diagram of Basic Toll Control Paths
Completely allowed
Allow all calls in home area code (local and toll)
Allow all calls to area codes 408, 209, 707
Deny all toll calls to other area codes
Allow toll calls to 613-592-2122
Deny operator access
Allow local calls only (primary calling area)
Deny operator access.
Completely allowed
Completely allowed
Deny Trunk access on other PABX (deny "9")
Allow everything else.
TRUNK
G R O U P
NO
PLAN
APPLIES
C O R MR
COR
NO
CONTROL
CONTROL
PLAN
PLAN
ASSIGNED
SECTION MITL9105/911
TRUNK
TRUNK GROUPS
GROUP
USED IN SYSTEM
NO
NO ABSORB
ABSORB
PLANS NEEDED
APPLIES
RESTRICTION USED
SELECTED BY
EXTENSION
(OR DIAL-INTRUNKj
PROGRAMMING
CLASSES OF
CONTROL
PLAN
ARE ASSIGNED
CONTROL PLANS
,