Mitel SX-200 Documentation page 752

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

SECTION
MITL91 OS/91 1 O-096-SOO-NA
L(
__ . . .
'L.
(
.:
TABLE 6-1
SYSTEM
FEATURE LIMITATIONS
Maximum
number
of simultaneous
calls = 31.
Maximum
number
of speech
paths
used by any call = 2.
Vlaximum
number
of simultaneous
consultations
= 15.
Vlaximum
number
of simultaneous
add-on
(3-way)
calls = 30.
Vlaximum
number
of simultaneous
station-controlled
conference
calls = 30.
Vlaximum
number
of calls that can simultaneously
be camped
on to an extension,
Trunk
Group
or Hunt Group
= 30.
Maximum
number
of simultaneous
Callbacks
that can be enabled
= 32
Maximum
number
of simultaneous
Call Forwards
that can be enabled
= 208 (SX-200);
112
(SX-100).
Maximum
number
of simultaneous
"dial 0" calls = 31.
Maximum
number
of Hunting
Groups
= 12.
Maximum
number
of calls that
can be simultaneously
connected
to Music on Hold = 31.
Maximum
number
of stations
in a Station
Hunting
Group
= 200 (SX-200);
112 (SX-100).
Maximum
number
of stations
in a Call Pickup Group
= 200 (SX-200);
112 (SX-100).
Maximum
number
of Dial Call Pickup Groups
= 30.
Maximum
number
of trunks
assignable
to Night
Stations
= 100 (SX-200);
52 (SX-100).
Maximum
number
of trunks
in a Trunk
Group
= 104 (SX-200);
56 (SX-100).
Maximum
number
of Trunk Groups
= 12.
Maximum
number
of calls that can override
a given
extension
= 1.
.'
Maximum
number
of calls that can be simultaneously
parked
= 31.
Maximum
number
of simultaneous
Meet-me
Conferences
= 1.
Maximum
number
of simultaneous
Attendant-controlled
conferences
= 1.
Maximum
number
of calls that can be simultaneously
held by one Attendant
= 4.
Maximum
number
of simultaneous
incoming
calls that can be separately
identified
by the
Attendant
= 6 (Recall, Dial 0, LDN 1 through
LDN 4).
Maximum
number
of LDNs that
can be identified
at the Attendant
Console
= 4.
Maximum
number
of simultaneously
ringing
Wake-ups
= 10.
Number
of Personal
Speed Call tables
= 25.
Maximum
number
of Common-use
Speed
Call tables
= 18.
System
numbering
schemes
may be l-, 2-, 3- or 4-digit
or a combination
of l-, 2-, 3- and
4-digit,
as long as there
are no conflicts
in the first
digits.
Maximum
number
of trunk
buffers
for SMDR = 45.
Maximum
number
of Speed Call digits
that
may be stored
= 56 (per table).
Maximum
number
of SUPERSET 4 Sets = 64.
Page 47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx-100