8. SUPERSET
Page 30
projects sound upwards through a grill beneath the handset. A screw-
driver slotted control for adjusting ringer pitch is user-accessible un-
derneath the base assembly.
Cover
Assembly
7.07
The cover assembly houses a volume control assembly, a key-
pad module, and a line selection/repertory dial module.
Volume
Control
Assembly
7.08
The volume control for the speaker and ringer, is mounted on
the left-hand side of the cover assembly. There is also a paper
for the installation telephone number, and the paper is held in place by
a transparent plastic lens that is clipped in position.
Keypad Module
7.09
The keypad module contains a standard 12-button keypad, sev-
en feature buttons, and three supplementary line select buttons.
Line Selection/Repertory Dial Module
7.10 The line selection repertory dial module contains three line
select buttons and LED line status display. In addition there are
12 Speed Call keys.
7.11
Associated with the keys and the line status display is a line
identification card. This card identifies the primary line
(extension) and hold buttons, and provides space for function iden-
tification (i.e., line and speed call identities) of the remaining buttons.
The card is held in place with a transparent plastic lens that is clipped
in position.
3 FUNCTIONAL DESCRIPTION
General
8.01
The SUPERSET 3 face layout is shown in Figure 6-2. The fol-
lowing text describes the function of each button and display.
All buttons are noninterlocking.
Line Select/Speed Call Buttons
8.02
There are three line select keys which can be configured (at the
time of programming) to select preassigned lines, in order to
receive or originate calls. In addition there are 12 Speed Call keys.
Hold Button
8.03
This button allows the set user to hold any call at the set. The
line on which the call is held is indicated by the adjacent line
status display flashing on and off. The call may be retrieved by press-
ing the HOLD Key.