RECEIVER BUSY-OUT
Description
This feature allows a particular receiver circuit to be busied-out or
debusied for maintenance purposes (i.e., pinpointing faulty receiver
circuitry). The receiver circuit may be busied-out from the test line or
from any console.
Conditions
None
Programming
An access code must be assigned to Feature Number 19
l
(Maintenance
Function).
Operation
(Where 555 is the Maintenance Function Code.)
To busy out a receiver circuit:
Dial 5553.
l
Dial equipment number of the receiver circuit.
l
Press RELEASE.
l
To debusy a receiver circuit:
Dial 5554.
l
Dial the equipment number of the receiver circuit.
l
Press RELEASE.
l
For information on equipment numbering of receiver circuits, see Sec-
tion MITL9105/91
SECTION MITL91 OS/91 10-096-l OS-NA
General Maintenance Information.
Page 221