Mitel SX-200 Documentation page 722

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

SECTION
MITL9105/911
O-096-500-NA
-
(4
W
Q
&I)
4.15
(a)
(b)
If any tone generator
has been busied-out,
this test is skipped.
(cl
The receiver
and generator
test is performed
for each of four
tone
digits
('1, 5, 9, a3 and for the
rotary
digit
"6". It is also
performed
for each pair of receivers
in the system.
If either
has
been busied-out
or if the receiver
card is not present,
the test
for that pair is skipped.
(d)
(4
The test is performed
once per pass for dial tone.
Using
each of the two
receivers
in turn, the test
waits
for the
receiver
to become
free, then
connects
it and the tone
to the
speech
path under
test. After
350 ms, the dial tone
detector
is
checked
to see if it has detected
the tone.
If neither
receiver
detected
the tone,
it is assumed
to be miss-
ing. Detection
of a malfunction
results
in ERROR 013 - testing
for supervisory
tone
presence
is no longer
performed.
If one
receiver
detected
the tone
but the
other
did not, it is
assumed
that the tone
is present
but one receiver
is faulty. This
results
in ERROR 014 - receiver
is busied-out.
Receiver
and Generator.
The receiver
and generator
test is as
follows:
This test
uses both
the speech
path
under
test
and the
15th
higher
speech
path.
If the speech
path
under
test
is numbered
17-31,
the test is skipped.
Each digit is sent eight
times,
using
all combinations
of the two
receivers,
two
speech
paths
and two
generators.
If any errors
are detected,
they
are analyzed
to see if they
correspond
to a
single
receiver,
speech
path
or generator
error.
If they
do, the
error is reported
as follows:
ERROR 008 (receiver,
tone,
error)
ERROR 009 (receiver,
rotary,
error)
ERROR 010 (generator
error)
ERROR 011 (error isolated
to a speech
path).
If it is not possible
to isolate
which
unit has failed,
the error
is
reported
as ERROR 015 - probable
receiver
error. The generator
is busied-out
to ensure
that the error
is not rereported
in each
pass.
Errors 008-010
result
in the receiver
or generator
being
busied-
out.
Error
011
could
be either
on the
receiver
card
or the
generator
card (tone
control
card), so no device
is busied-out.
Page 17