SX-100 Primary Power Supply
2.13
The system primary power supply (total weight 6.8 kg (15 lb)) is
mounted to the right of the equipment shelf (see Figure 2-2). It
provides all system power from 115 Vat, 48 Hz to 64 Hz commercial
power supply. With a special 230 Vat adapter, the SX-100 system may
be operated from 230 Vat 48 Hz to 64 Hz.
SX-200 Primary Power Supply
2.14
The system primary power supply (total weight 32 kg (70 lb)) is
mounted directly on the cabinet back panel (see Figure 2-3). It
provides all system power from 115 Vat or 230 Vat, 48 Hz to 64 Hz
commercial power supply.
Reserve Power Supply
2.15 The reserve power supply is designed to maintain complete
system operation for a minimum of 2 hours in the event of a
commercial power failure. The batteries and the charger are enclosed
in a metal casement that forms a pedestal for the SX-100 equipment
cabinet, weighing a total of 56.7 k g (125 lb). The SX-200 reserved
Figure 2-6 Typical Printed Circuit Card