.I.
DATA DEMULTIPLEXER
Description
The Data Demultiplexer allows a different recording device to be used
for: Traffic Measurement, SMDR, Hotel/Motel and Maintenance.
Conditions
The Scanner card and the Data Demultiplexer card must have the
l
same switch settings for: Baud rate, character length, parity and
stop bit selection.
Programming
Select System Option 151 (Data Demultiplex Enable).
l
Ensure the Printer is set for the same Baud rates, character
l
length, parity and stop bit selection as the Scanner Card and
Data Demultiplexer.
Operation
See Automatic Wake-Up, Customer Data Print, Customer Data Dump
Load, Station Message Detail Recording and Section MITL9160-
.
SECTION MITL91 OS/91 1 O-096-105-NA