may be assigned to a COR and the same Control Plan may be
assigned to more than one Class of Restriction. Each defined
Control Plan can be enabled to cause an unconditional denial of
a call if a toll reversal is sensed. Note that the first digit of the
Trunk Group "type" must be programmed as "3" to indicate that
a reversal on the trunk represents toll call detection by the
Central Office.
6.09 The Control Plan contains the basic Allow/Deny information.
This includes information for denying if a 'Toll Reversal" is
sensed, and five "Basic Conditions" of Allow/Deny. The Control Plan
also designates any required table(s) of exceptions to the five basic
conditions.
6.10
The basic Allow/Deny conditions fall into three groups and only
one of these groups will be involved in any single dialing
instance. The three groups and the basic Allow/Deny conditions listed
as (1 through 5) are as follows:
(a)
First digit (after absorbs) is a 0
1. Allow/Deny 1st digit 0.
(b)
First digit (after absorbs) is a 1
2. Allow/Deny l-XNX
3. Allow/Deny 1 -X0/1X.
(c)
First digit (after absorbs) is a 2-9
4. Allow/Deny NNX
5. Allow/Deny NO/lx.
6 . 1 1
I nit ia lizing a T a ble .
required for different entries, it may be cleared of all entries
and expansions via initialization. The suggested programming form
shows the procedure.
6 . 1 2
Ex a m ining a nd Adding/De le t ing T a ble Ent rie s.
manipulated on an entry basis. Inspecting the programming
procedure form for table manipulation will reveal that there are four
basic entry operations once the table number has been entered and
DISPLAY ENTRY button has been pressed:
1 .
Display next entry in table.
2.
Search for specific entry.
3. Add a specific entry to the table, including an optional table
number of an expansion to the entry.
4.
Delete the entry currently being displayed from the table.
SECTION MITL91 OS/91 1 O-096-212-NA
If a table which was previously in use is
Tables may be
Page 17