Mitel SX-200 Documentation page 670

Superswitch electronic private automatic branch exchange epabx
Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

Remote
Operation
SECTION
MITL9105/911
O-096-450-NA
6.07
When
the
required
System
Options
have
been
entered
in the
PABX, the
necessary
operations
to obtain
traffic
measurement
data at the remote
location
are as follows:
(a)
Polling
Mode.
To
request
traffic
data,
the
character
DC1
or
NULL is transmitted
from
the remote
terminal
to the PABX data
port. The NULL code also results
when
a BREAK is sent from
the
remote
equipment.
Hence
a BREAK may
be used
to
initiate
polling.
These
characters
are ignored
while
in the
middle
of
outputting
a report.
On receipt
of any one
of these
signals,
traffic
data
will
then
be transmitted
from
the
PABX to
the
remote
device
over the line. To suspend
the flow
of traffic
data,
the
character
DC3 is sent
from
the remote
terminal.
This will
immediately
suspend
the traffic
data flow. Traffic
data flow
may
be resumed
by transmission
of character
DCl.
(b)
Autoprint
Mode.
If System
Option
295 (Autoprint)
is selected,
hourly
traffic
measurement
data
is transmitted
automatically
from
the PABX data port.
Note that
if this data is to be printed
on a local printer,
and
a
Hotel/Motel
printout
is requested
dur-
ing an Autoprint
printout,
then
the Hotel/Motel
printout
will not
occur
until after the completion
of the Autoprint
report.
f
L..
Console
Operation
6.08
Traffic
Measurement
data
may
be obtained
by console
com-
mands.
The appropriate
commands
are listed in Table 6-3. Sys-
tem Options
298 and/or
297 must
have been enabled.
Note that Polling
mode
is not applicable
for local printer
operation,
but Autoprint
mode
can be employed
(see paragraph
6.07(b)).
CAUTION:
It should
be
noted
that
reprogramming
trunks
and
trunk
groups
in the
middle
of
a Traffic
Measurement
run may cause
invalid
data
results.
Additional
Operating
Notes
6.09
The following
additional
operating
procedures
should
be noted:
(a)
The
Start
and
Run times
must
be selected
by the
console,
irrespective
of the type (polling,
autoprint
or console)
of output.
.
(b)
If System
Option
298
and
297
are
not
selected,
the
traffic
utilities
are illegal.
(c)
If the
attendant
resets
the digital
clock
during
a traffic
run, a
traffic
report
could
be missed
or printed
twice.
For example,
assume
that Autoprint
is in effect
and a Traffic
Report
is due at
10:OO. If the clock is reset from
9:55 to 10:05, the report
will be
lost. If it is reset
from
lo:05
to 9:55, two reports
will be printed
of the
10:00
to 11:OO
data.
The attendant
should
be cautioned
against
resetting
the clock around
the time of a Traffic
Report.
Page
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx-100

Table of Contents