D
IF
FER
E
NTIAL
RE
-ASSEMBLY -
ADJUSTMENT
Place
micrometer on
right-hand side plate
with dial indicator feeler on outside machined
surface of plate.
- Adjust dial indicator height so as to obtain o
reading of
"l"
and
"O"
for example.
- Place micrometer on machined surface of
tool
AZ
used as measuring
surface
.
- The displacement of the dial indicator needles
represents the height of the collar on plate.
Ex.:
Measurement on plate
l .00
Measurement on measuring surface
7 .29
Height
of collar
6.29
Compare
:
-
number obtained when measurement on housing
was carried out.
-
the height of the collar.
- THE DIFFERENCE ROUNDED TO THE NEA
-
REST 0 .05 mm REPRESENTS THE THICK-
NESS OF THE SHIMS TO BE INSTALLED
BETWEEN BEARING AND THRUST PLATE
(4th
adjustment).
Ex.:
Number obtained with first measurement 6.40
He
ight of coll or
6.29
Thickness of shims to be used
0.1 l
which means
0.10