47.3 Ethernet Connection

47.3.1 System Configuration for connecting to MICREX-SX SPH

MICREX-SX SPH
PLC
Connection cable
Ethernet
Model
interface
name
*4
module
SPH200
SPH300
NP1L-ET1
SPH2000
SPH3000
• 10BASE-T
Shielded twisted pair
cable (STP) or
unshielded twisted pair
cable (UTP) :
Category 3, 4, and 5
• 100BASE-TX
SPH2000
-
Shielded twisted pair
SPH3000
cable (STP):
Category 5 and 5e
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
Use C or later version of GT11H-C-37P.
*4
Product manufactured by Fuji Electric Co., Ltd. For details of the product, contact Fuji Electric Co., Ltd.
Ethernet
interface
module
Connection cable
*1
Connector
conversion box
Cable model
GT16H-CNB-42S
GT16H-CNB-37S
GT16H-CNB-42S
GT16H-CNB-37S
Connector
conversion
box
External cable
GOT
*3
External cable
Model
GT14H-C30-42P (3m)
GT14H-C60-42P (6m)
GT14H-C100-42P (10m)
GT11H-C30-37P (3m)
GT11H-C60-37P (6m)
GT11H-C100-37P(10m)
GT14H-C30-42P (3m)
GT14H-C60-42P (6m)
GT14H-C100-42P (10m)
GT11H-C30-37P (3m)
GT11H-C60-37P (6m)
GT11H-C100-37P (10m)
47. CONNECTION TO FUJI PLC
47.3 Ethernet Connection
Communication driver
Ethernet(
), Gateway
FUJI
GOT
Maximum
Number of connectable
segment
Model name equipment
length
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1
PLC 128 or less
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1
PLC 8 or less
*2
100m
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1
PLC 128 or less
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1
PLC 10 or less
47 - 35