52.5.17 Connecting to AHC2001 CPU
module
Communication settings
Make the communication settings by operating the key
of the temperature controller or Smart Loader Package
(SLP-D50 or SLP-H21).
Item
*1
9600bps, 19200bps, 38400bps, 57600bps
Transmission speed
*2
1:CPL
Mode
Data bit
8bits (fixed)
Parity bit
Even (fixed)
Stop bit
1bit (fixed)
*3
*4
Station address
1 to 15
*1
The transmission speed setting must be consistent with that
of the GOT side.
*2
Set to 1:CPL.
*3
Select the station address without overlapping with that of
other units.
*4
Although the device address range of AHC2001 is 1 to 127,
use the device setting range of DMC50 of 1 to 15.
52.5.18 Connecting to AHC2001 SCU
module
Communication settings
Make the communication settings by operating the key
of the temperature controller or Smart Loader Package
(SLP-D50 or SLP-H21).
Item
*1
9600bps, 19200bps, 38400bps
Transmission speed
*2
2:CPL
Protocol setting
*1
7bits, 8bits
Data bit
*1
0: None, 1: Even, 2: Odd
Parity bit
*1
1bit, 2bits
Stop bit
*3
0: Half-duplex
Half-duplex/Duplex
Spacing transmission
0 (fixed)
*1
Adjust the settings of transmission speed, data length, parity
bit, and stop bit with that of the GOT.
*2
Set to 2:CPL.
*3
Set to 0: Half-duplex.
Set value
Set value
52. CONNECTION TO AZBIL CONTROL EQUIPMENT

52.5.19 Station number setting

Set each station number so that no station number overlaps.
The station number can be set without regard to the cable
connection order. There is no problem even if station
numbers are not consecutive.
Station
Station
No.3
No.10
GOT
Examples of station number setting
(1) Direct specification
When setting the device, specify the station number of
the control equipment of which data is to be changed.
Model
SDC40A/40B/40G, SDC15,
SDC25/26, SDC35/36,
SDC20/21, SDC30/31,
CML, CMF050, MQV, MPC
PBC201-VN2
SDC45/46
CMS, CMF015, CMC10B
RX
DMC10, DMC50, MVF,
AUR350C, AUR450C, AHC2001
*1
Although the station number range of AHC2001 is 1 to 127,
use the station number range of DMC50 of 1 to 15.
(2) Indirect specification
When setting the device, indirectly specify the station
number of the control equipment of which data is to be
changed using the 16-bit GOT internal data register
(GD10 to GD25).
When specifying the station No. shown in the table
below on GT Designer3, the value of GD10 to GD25
compatible to the station No. specification will be the
station No. of the control equipment.
Specification
station No.
Compatible
device
DMC50
Except
AHC2001
DMC50
100
200
GD10
101
201
GD11
102
202
GD12
103
203
GD13
104
204
GD14
105
205
GD15
106
206
GD16
107
207
GD17
108
208
GD18
109
209
GD19
110
210
GD20
111
211
GD21
112
212
GD22
113
213
GD23
114
214
GD24
115
215
GD25
*1
Although the station number range of AHC2001 is 1 to 127,
use the station number range of DMC50 of 1 to 15.
52.5 Control Equipment Side Setting
Station
Station
Station
No.1
No.15
No.6
Specification range
1 to 127
1 to 126
1 to 120
1 to 99
1 to 32
1 to 15
*1
Setting range
1 to 127: SDC40A/40B/40G,
SDC15, SDC25/26,
SDC35/36, SDC20/21,
SDC30/31, CML,
CMF050, MQV, MPC
1 to 126: PBC201-VN2
1 to 120: SDC45/46
1 to 99:
CMS, CMF015, CMC10B
1 to 32:
RX
1 to 15:
DMC10, DMC50, MVF,
AUR350C, AUR450C,
*1
AHC2001
For the setting other than the above,
an error (dedicated device is out of
range) will occur.
52 - 43