(2) Setting for the built-in MP2300S Ethernet and 218IF-02
Make the parameter settings with a peripheral tool.
Item
IP Address
Transmission
Subnet Mask
parameter
Gateway IP Address
setting
Device name
Engineering Port
Transmission
parameter
detailed
Response Time
setting
Count of Retry
(Number of Retries)
Connection Number
Local Port
Node
*1
IP Address
Message
*1
communicati
Node Port
on of
Connection Type
connection
parameter
setting
Protocol Type
Code
Node Name (Remote
Station's Name)
*1
Set the same the Node IP Address (Remote Station's IP
Address) and the Node Port (Remote Station's Port Number)
as the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side.
For the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side, refer to the following.
49.3.2 Ethernet setting
(3) Setting of 218TXB
(a) DIP switch (SW2) setting
Set all the "unused" switches to off. When the
"unused" switches are on, the PLC does not
operate properly. In addition, when the PLC is
operated with the TEST switch on, the module
shifts to the self-check mode and communication is
disabled. To start communication, turn the TEST
switch to off.
SW2
ON
49 - 26
49. CONNECTION TO YASKAWA PLC
49.3 Ethernet Connection
Set value
Range
PLC side IP
[ ].[ ].[ ].[ ]
address
[ ].[ ].[ ].[ ]
PLC side setting
[ ].[ ].[ ].[ ]
Up to 16 one-byte
Arbitrary
characters
For a connection
256 to 65535
with software
MPE720
0
Not required for
communication
0
with GOT
• Range of built in
MP2300S
Ethernet: 1 to 4
1
• Range of 218IF-
02: 1 to 20
10500
256 to 65534
GOT side IP
[ ].[ ].[ ].[ ]
address
[ ]
GOT side port No.
UDP
UDP/TCP
(recommended)
Extended
MEMOBUS,
Extended
MEMOBUS,
MEMOBUS
MELSEC,
None,
MODBUS/TCP
BIN
RTU, BIN, ACII
Up to 32 one-byte
Arbitrary
characters (16 two-
byte characters)
N/O
10/100
F/H
INIT
TEST
OFF
Stat
Display
Name
us
ON
(13 channels, Max. 1024 words)
Mode
N/O
selection
OFF
(10 channels, Max. 512 words)
-
Unused
Transmis
ON
10/100
sion
OFF
speed
Transmis
ON
Full duplex mode communication
F/H
sion
OFF
Half duplex mode communication
mode
Startup with the default IP address
ON
and the default engineering port No.
Initial
INIT
startup
Startup with the IP address and the
OFF
engineering port No set in CP-717.
ON Self check (Self check is conducted
TEST
TEST
when the module is started with the
OFF
(b) Parameter setting
Make the parameter settings with a peripheral tool.
Item
IP Address
Transmission
Subnet Mask
parameter
Gateway IP Address
setting
Device name
Engineering Port
Transmission
parameter
Response Time
detailed setting
Count of Retry
(Number of Retries)
Message
Connection Number
communication
of connection
parameter
setting
Local Port
Node IP Address
*1
Node Port
Connection Type
Message
communication
Protocol Type
of connection
parameter
setting
Code
Node Name
(Remote Station's
Name)
*1
Set the same the Node IP Address (Remote Station's IP
Address) and the Node Port (Remote Station's Port Number)
as the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side.
For the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side, refer to the following.
49.3.2 Ethernet setting
Operation
Set value
Extended mode
(Extended
Basic mode
mode)
10Mbs
(100Mbps)
100Mbps
(Half duplex
mode)
TEST switch on.)
Set value
Range
PLC side IP
[ ].[ ].[ ].[ ]
address
[ ].[ ].[ ].[ ]
PLC side setting
[ ].[ ].[ ].[ ]
Up to 16 one-byte
Arbitrary
characters
For a connection
256 to 65535
with software
MPE720
0
Not required for
communication
0
with GOT
• Range of built
in MP2300S
Ethernet: 1 to 4
1
• Range of
218IF-02: 1 to
20
10500
256 to 65534
GOT side IP
*1
[ ].[ ].[ ].[ ]
address
[ ]
GOT side port No.
UDP
UDP/TCP
(recommended)
Extended
MEMOBUS,
Extended
MEMOBUS,
MEMOBUS
MELSEC, None,
MODBUS/TCP
BIN
RTU, BIN, ACII
Up to 32 one-byte
characters (16
Arbitrary
two-byte
characters)
ON
OFF
OFF
OFF
OFF
OFF