53.2.7 Connecting to PF900/901, HA400/401, HA900/901, RMC500, MA900/
MA901, AG500, THV-A1, SA100/200
When connecting to temperature controller
(1) When using the connector conversion box
Temperature
controller
Connection cable 1)
Temperature controller
Connection cable 1)
Communicat
Cable model
Model
ion type
Connection diagram number
PF900/901
HA400/401
RS-232
HA900/901
MA900/901
PF900/901
HA400/401
RS422 connection
HA900/901
RS-422
diagram 5)
MA900/901
AG500
W-BF-02-0500(0.5m)
W-BF-02-1000(1m)
THV-A1
RS-422
W-BF-02-3000(3m)
*1
The distance from the GOT to the temperature controller (Connection cable 1) + Connection cable 2) + External cable)
*2
Product manufactured by RKC. For details of the product, contact RKC.
Temperature
controller
Connection cable 2)
Connection cable 2)
Cable model
Connection diagram number
RS232 connection
-
diagram 4)
RS422 connection
diagram 6)
RS422 connection
diagram 1)
*2
53. CONNECTION TO RKC TEMPERATURE CONTROLLER
Connector
conversion
box
External cable
Connector
External cable
conversion box
GT11H-CNB-37S
GT11H-C30-37P(3m)
GT11H-C30-37P(3m)
GT11H-CNB-37S
GT11H-C60-37P(6m)
GT11H-C100-37P(10m)
GT11H-C30-37P(3m)
GT11H-CNB-37S
GT11H-C60-37P(6m)
GT11H-C100-37P(10m)
53.2 System Configuration
GOT
Number of
Total
GOT
connectable
distance
model
equipment
*1
1 temperature
6m
controller for
1 GOT
Up to 10
temperature
13m
controllers for
1 GOT
Up to 10
temperature
13m
controllers for
1 GOT
53 - 21