11.3 Operation Settings (Settings Regarding Operation)

11.3.1
Operation setting functions
Setting regarding GOT operation can be set.
The items which can be set are described below. If touch the each item part, the respective setting becomes possible.
Function
Buzzer volume setting
Window move buzzer volume
setting
Security setting screen change
Utility call key screen change
Key sensitivity setting
Touch panel calibration
Touch detection mode
USB mouse/keyboard setting
SoftGOT-GOT link function setting
VNC
server function setting
*1
Relation between the [Key sensitivity] setting and [Key reaction speed]
The larger the set value in [Key sensitivity] is, the shorter the time taken from touching the touch panel until the GOT responds
becomes.
E.g. decrease the value set for [Key sensitivity] when double-touch is made when touching the GOT screen only once. (Decrease
the reaction speed.)
The relation between the [Key sensitivity] setting and [Key reaction speed] is as follows.
[Key sensitivity] setting
[Key reaction speed]
11 - 18
11. DISPLAY AND OPERATION SETTINGS (GOT SET UP)
11.3 Operation Settings (Settings Regarding Operation)
Description
Buzzer volume setting can be changed.
Whether turn ON/OFF buzzer when move window can be
selected.
Security level change screen can be displayed.
11.3.4Security level change
Utility call key setting screen can be displayed.
11.3.5Utility call key setting
The touch panel sensitivity when touching the GOT screen can
be set.
E.g. a setting can be changed when double-touch is made
when touching the GOT screen only once. (For preventing
chattering)
Touch panel reading error can be corrected.
11.3.6Adjusting the touch panel position (Touch panel
calibration setting)
Whether to reduce incorrect inputs (responses of parts other
than the touched part) when more than 2 points are touched
simultaneously on the GOT or to prioritize response can be
selected.
Set the setting items related with USB mouse/keyboard.
11.3.7 USB mouse/keyboard setting
The authorization of the SoftGOT-GOT link function can be set,
and the exclusive authorization can be obtained or released.
11.3.8 SoftGOT-GOT Link Function Setting
The authorization guarantee time for the VNC
function can be set.
Quick response ←
8
7
-20ms
-10ms
(Standard)
server
6
5
4
±0ms
+10ms
+20ms
Setting range
OFF/SHORT/LONG
<At factory shipment: SHORT>
ON/OFF
<At factory shipment: ON>
-
-
*1
1 to 8
-
Continuous key input/Avoid
input error
<Default:
Continuous key input>
-
-
0 to 3600 seconds
<At factory shipment: 0
seconds>
→ Slow response
3
2
1
+40ms
+80ms
+120ms