Dell Z9500 Command Reference Manual page 1756

Hide thumbs Also See for Z9500:
Table of Contents

Advertisement

Message ID
%CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power
supply redundant
CHM_MIN_ALRM_TEMP
%CHMGR-2-MINOR_TEMP: Minor alarm: chassis
temperature
CHM_MIN_ALRM_TEMP_CLR
%CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared:
chassis temperature normal (%s %d temperature is
within threshold of %dC)
CHM_MAJ_ALRM_TEMP
%CHMGR-2-MAJOR_TEMP: Major alarm: chassis
temperature high (%s temperature reaches or exceeds
threshold of %dC)
CHM_MAJ_ALRM_TEMP_CLR
%CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared:
chassis temperature lower (%s %d temperature is
within threshold of %dC)
CHM_FANTRAY_BAD
%CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is
missing or down
%CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan
tray %d are down.
%CHMGR-2-FANTRAYBAD: Major alarm: fan tray is
missing
%CHMGR-2-FANSBAD: Major alarm: most or all fans in
fan tray are down
CHM_FANTRAY_BAD_CLR
%CHMGR-5-FAN_TRAY_OK: Major alarm cleared: fan tray
%d present
%CHMGR-5-FANTRAYOK: Major alarm cleared: fan tray
present
CHM_MIN_FANBAD
%CHMGR-2-FAN_BAD: Minor alarm: some fans in fan
tray %d are down
%CHMGR- 2-1FANBAD: Minor alarm: fan in fan tray is
down
CHM_MIN_FANBAD_CLR
%CHMGR-2-FAN_OK: Minor alarm cleared: all fans in
fan tray %d are good
1756
Trap Type
Trap Option
ENVMON
TEMP
ENVMON
TEMP
ENVMON
TEMP
ENVMON
TEMP
ENVMON
FAN
ENVMON
FAN
ENVMON
FAN
ENVMON
FAN
SNMP Traps

Advertisement

Table of Contents
loading

Table of Contents