3.2.4.10

set lldp hold-multiplier

Use this command to set the time-to-live value used in LLDP frames sent by this device. The
time-to-live for LLDPDU data is calculated by multiplying the transmit interval by the hold
multiplier value.
set lldp hold-multiplier multiplier-val
Syntax Description
multiplier-val
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example sets the transmit interval to 20 seconds and the hold multiplier to 5, which will
configure a time-to-live of 100 to be used in the TTL field in the LLDPDU header.
Matrix(rw)->set lldp tx-interval 20
Matrix(rw)->set lldp hold-multiplier 5
Link Layer Discovery Protocol and LLDP-MED
Specifies the multiplier to apply to the transmit interval to
determine the time-to-live value. Value can range from 2
to 10. Default value is 4.