Table of Contents
loading

Summary of Contents for Enterasys Enterasys SecureStack A2 A2H254-16

  • Page 1 SecureStack A2 Fast Ethernet Switches Hardware Installation Guide A2H254-16 P/N 9034173...
  • Page 3 Electrical Hazard: Only qualified personnel should perform installation procedures. Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Enterasys Networks reserves the right to make changes in specifications and other information contained in this  document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to  determine whether any such changes have been made. The hardware, firmware, or software described in this document is subject to change without notice. IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR  CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING  OUT OF OR RELATED TO THIS DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN THEM, EVEN  IF ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNEW OF, OR SHOULD HAVE KNOWN OF, THE  POSSIBILITY OF SUCH DAMAGES. Enterasys Networks, Inc.
  • Page 4: Regulatory Compliance Information

    Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device  may not cause harmful interference, and (2) this device must accept any interference received, including interference  that may cause undesired operation. NOTE:  This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to  Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when  the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio  frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to  radio communications. Operation of this equipment in a residential area is likely to cause interference in which case  the user will be required to correct the interference at his own expense. WARNING:  Changes or modifications made to this device which are not expressly approved by the party  responsible for compliance could void the user’s authority to operate the equipment. Industry Canada Notice This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the  Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils  numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des  Communications du Canada. Class A ITE Notice WARNING:  This is a Class A product. In a domestic environment this product may cause radio interference in which  case the user may be required to take adequate measures.  Clase A. Aviso de ITE ADVERTENCIA: Este es un producto de Clase A. En un ambiente doméstico este producto puede causar ...
  • Page 5 Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000‐3‐2,  EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3.  Compatibilidad Electromágnetica (EMC) Este producto de Enterasys cumple con lo siguiente: 47 CFR Partes 2 y 15, CSA C108.8, 89/336/EEC, EN 55022,  EN 55024, EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3. Elektro- magnetische Kompatibilität (EMC) Dieses Produkt entspricht den folgenden Richtlinien: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022,  EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3.  VCCI Notice This is a class A product based on the standard of the Voluntary Control Council for Interference by Information  Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise.  When such trouble occurs, the user may be required to take corrective actions. BSMI EMC Statement — Taiwan This is a class A product. In a domestic environment this product may cause radio interference in which case the user  may be required to take adequate measures.
  • Page 6: Safety Information

    European Waste Electrical and Electronic Equipment (WEEE) Notice In accordance with Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment  (WEEE): The symbol above indicates that separate collection of electrical and electronic equipment is required and that this  product was placed on the European market after August 13, 2005, the date of enforcement for Directive  2002/96/EC. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste.  It must be collected and treated separately. It has been determined by the European Parliament that there are potential negative effects on the environment  and human health as a result of the presence of hazardous substances in electrical and electronic equipment. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated. For information about the available collection system, please go to http://www.enterasys.com/support/ or contact  Enterasys Customer Support at 353 61 705586 (Ireland). The single mode interface modules use Class 1 laser transceivers. Read the following safety information before installing or operating these modules. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop ...
  • Page 7: Declaration Of Conformity

    Declaration of Conformity Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’s Address: 50 Minuteman Road Andover, MA 01810 European Representative Address: Enterasys Networks, Ltd. Nexus House, Newbury Business Park London Road, Newbury Berkshire RG14 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EN 55022 EN61000‐3‐2 EN61000‐3‐3 EN 55024 EC Directive 73/23/EEC EN 60950 EN 60825 Equipment Type/Environment: Networking Equipment, for use in a Commercial  or Light Industrial Environment. Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above directives.
  • Page 8 ENTER INTO THIS AGREEMENT, ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU  AGREE TO RETURN THE UNOPENED PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN  (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND. IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS, LEGAL  DEPARTMENT AT (978) 684‐1000.  You and Enterasys agree as follows: LICENSE.  You have the non‐exclusive and non‐transferable right to use only the one (1) copy of the Program  provided in this package subject to the terms and conditions of this Agreement. RESTRICTIONS.  Except as otherwise authorized in writing by Enterasys, You may not, nor may You permit any  third party to: (i) Reverse engineer, decompile, disassemble or modify the Program, in whole or in part, including for reasons  of error correction or interoperability, except to the extent expressly permitted by applicable law and to the  extent the parties shall not be permitted by that applicable law, such rights are expressly excluded.  Information necessary to achieve interoperability or correct errors is available from Enterasys upon request  and upon payment of Enterasys’ applicable fee. (ii) Incorporate the Program, in whole or in part, in any other product or create derivative works based on the  Program, in whole or in part. (iii) Publish, disclose, copy, reproduce or transmit the Program, in whole or in part. (iv) Assign, sell, license, sublicense, rent, lease, encumber by way of security interest, pledge or otherwise transfer  the Program, in whole or in part. (v) Remove any copyright, trademark, proprietary rights, disclaimer or warning notice included on or embedded  in any part of the Program. Enterasys Networks, Inc. Firmware License Agreement CAREFULLY READ THIS LICENSE AGREEMENT.
  • Page 9 APPLICABLE LAW.  This Agreement shall be interpreted and governed under the laws and in the state and  federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the  personal jurisdiction and venue of the Commonwealth of Massachusetts courts. None of the 1980 United Nations  Convention on Contracts for the International Sale of Goods, the United Nations Convention on the Limitation Period  in the International Sale of Goods, and the Uniform Computer Information Transactions Act shall apply to this  Agreement.  EXPORT RESTRICTIONS.  You understand that Enterasys and its Affiliates are subject to regulation by agencies  of the U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain  technical products to certain countries, unless a license to export the Program is obtained from the U.S. Government or  an exception from obtaining such license may be relied upon by the exporting party. If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export  Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the  Program for civil end uses only and not for military purposes.  If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export  Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You  agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country  in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia,  Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China,  Romania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be  designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct  product of the Program or the technology, if such foreign produced direct product is subject to national security  controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a complete  plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major  component thereof, if such foreign produced direct product is subject to national security controls as identified on the  U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List. UNITED STATES GOVERNMENT RESTRICTED RIGHTS.  The enclosed Program (i) was developed solely at  private expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section  52.227‐19 (a) through (d) of the Commercial Computer Software‐Restricted Rights Clause and its successors, and (iii) in  all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the  Program is considered commercial computer software in accordance with DFARS section 227.7202‐3 and its successors,  and use, duplication, or disclosure by the Government is subject to restrictions set forth herein.  DISCLAIMER OF WARRANTY.  EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN  WRITING BY Enterasys, Enterasys DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING  BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS  FOR A PARTICULAR PURPOSE, TITLE AND NON‐ INFRINGEMENT WITH RESPECT TO THE PROGRAM. IF  IMPLIED WARRANTIES MAY NOT BE DISCLAIMED BY APPLICABLE LAW, THEN ANY IMPLIED WARRANTIES  ARE LIMITED IN DURATION TO THIRTY (30) DAYS AFTER DELIVERY OF THE PROGRAM TO YOU. ...
  • Page 10 AUDIT RIGHTS.  You hereby acknowledge that the intellectual property rights associated with the Program are  of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts  showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to  Enterasys and its authorized representatives, upon reasonable notice, the right to audit and examine during Your  normal business hours, Your books, records, accounts and hardware devices upon which the Program may be deployed  to verify compliance with this Agreement, including the verification of the license fees due and paid Enterasys and the  use, copying and deployment of the Program. Enterasys’ right of examination shall be exercised reasonably, in good  faith and in a manner calculated to not unreasonably interfere with Your business. In the event such audit discovers  non‐compliance with this Agreement, including copies of the Program made, used or deployed in breach of this  Agreement, You shall promptly pay to Enterasys the appropriate license fees. Enterasys reserves the right, to be  exercised in its sole discretion and without prior notice, to terminate this license, effective immediately, for failure to  comply with this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall  return to Enterasys the Program and all copies of the Program. OWNERSHIP.  This is a license agreement and not an agreement for sale. You acknowledge and agree that the  Program constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to  implement reasonable security measures to protect such trade secrets and copyrighted material. All right, title and  interest in and to the Program shall remain with Enterasys and/or its suppliers. All rights not specifically granted to  You shall be reserved to Enterasys. 10. ENFORCEMENT.  You acknowledge and agree that any breach of Sections 2, 4, or 9 of this Agreement by You may  cause Enterasys irreparable damage for which recovery of money damages would be inadequate, and that Enterasys  may be entitled to seek timely injunctive relief to protect Enterasys’ rights under this Agreement in addition to any and  all remedies available at law.  11. ASSIGNMENT.  You may not assign, transfer or sublicense this Agreement or any of Your rights or obligations  under this Agreement, except that You may assign this Agreement to any person or entity which acquires substantially  all of Your stock or assets. Enterasys may assign this Agreement in its sole discretion. This Agreement shall be binding  upon and inure to the benefit of the parties, their legal representatives, permitted transferees, successors and assigns as  permitted by this Agreement. Any attempted assignment, transfer or sublicense in violation of the terms of this  Agreement shall be void and a breach of this Agreement. 12. WAIVER.  A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in  writing and will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to  enforce a term upon Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement  on any other occasion. 13.
  • Page 11: Table Of Contents

    Required Tools ...3-2 Unpacking the Switch ...3-2 Installing Optional Mini-GBICs ...3-3 Removing the Mini-GBIC ...3-6 Installing the Switch on a Flat Surface ...3-7 Installing the Rubber Feet ...3-7 Guidelines for Flat Surface Installation ...3-8 Rack Mounting the Switch ...3-9 Guidelines for Rackmount Installation ...3-10 Attaching Brackets and Installing in Rack ...3-10...
  • Page 12 Configuring Switches in a Stack ...3-12 About SecureStack A2 Switch Operation in a Stack ...3-12 Recommended Procedures for New and Existing Stacks ...3-14 Connecting AC and RPS-SYS Power ...3-15 AC Power ...3-15 C2RPS-SYS Redundant Power System ...3-17 Stack Initialization Overview ...3-18 Connecting to Console Port for Local Management ...3-18...
  • Page 13 Mini-GBIC with RJ45 Connector ...3-4 Mini-GBIC with MT-RJ Connector...3-5 Mini-GBIC with LC Connector ...3-6 Chassis Bottom, Rubber Feet Placement ...3-8 Area Guidelines for Switch Installation on Flat Surface ...3-9 Attaching the Rackmount Brackets ...3-10 Fastening the Switch to the Rack...3-11 Stacking Cable Connections ...3-12 Switch Rear View ...3-16...
  • Page 15: About This Guide

    MGBIC slots. Depending on the firmware version used in the A2H254-16 switch, some features described in this document may not be supported. Refer to the Release Notes shipped with the SecureStack A2 to determine which features are supported.
  • Page 16: How To Use This Guide

    How to Use This Guide How to Use This Guide Read through this guide completely to familiarize yourself with its contents and gain an  understanding of the features and capabilities of the stackable Ethernet switch. A general  knowledge of data communications networks is helpful when setting up the switch.  This preface provides an overview of this guide and the SecureStack A2 manual set, a  brief summary of each chapter and defines the conventions used throughout this guide.  To locate information concerning various subjects in this guide, refer to the following  table: For... An overview of the SecureStack A2 features and how to obtain technical support Network requirements that must be met before installing the SecureStack A2...
  • Page 17: Conventions Used In This Guide

    Conventions Used in This Guide Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader’s attention to any item of information that may be of special importance. Caution: Contains information essential to avoid damage to the equipment. Precaución: Contiene información esencial para prevenir dañar el equipo. Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
  • Page 18 Conventions Used in This Guide xvi About This Guide...
  • Page 19: Overview

    This chapter introduces the A2H254‐16 stackable Fast Ethernet switch.  Depending on the firmware version used in the SecureStack A2, some features described in this document may not be supported. Refer to the Release Notes shipped with the A2H254-16 to determine which features are supported. For information about... Overview...
  • Page 20: Overview

    De lo contrario, el dispositivo puede dañarse. Note: The 1000BASE-T built-in RJ45 stacking ports 17 and 18 on the A2H254-16 can be configured as standard 10/100/1000BASE-T switch ports, using the command “set switch stackport <ethernet | stack>” when the unit is in standalone mode (not stacked).
  • Page 21: Stack Connections

    Figure 1-1 A2H254-16 Stackable Switch 1 DB9 RS232 Console port connector 2 Recessed password reset button 3 Stack Unit status LED 4 Status LEDs for ports 1-16 5 8 RJ45 ports (Odd numbered 1-15) 6 8 MT-RJ ports (Even numbered 2-16) Stack Connections The switch has front‐panel RJ45 ports 17 and 18 for connections in a stack configuration. ...
  • Page 22: Connectivity

    Connectivity Connectivity The SecureStack A2 switch connects to Ethernet networks or workstations via the fixed  front panel MT‐RJ and RJ45 ports and the two SFP uplink ports that support optional  Mini‐GBICs. At the time of this printing, the Mini‐GBICs that are available from Enterasys and  supported by the A2 switch are described in Table 1‐1. These Mini‐GBICs meet or exceed  the IEEE 802.3z‐1998 standard. Table 1-1 Description of Mini-GBICs Mini-GBIC MGBIC-LC01 MGBIC-LC03 MGBIC-LC09 MGBIC-MT01 MGBIC-08 MGBIC-02 1-4 Introduction Specification Provides one 1000BASE-SX compliant LC fiber-optic multimode port and a standard LC connector. For optical and operating range specifications, refer to “MGBIC-LC01/MGBIC-MT01 Specifications...
  • Page 23: Management

    Management Management of the module can be either in‐band or out‐of‐band. In‐band remote  management is possible using Telnet, Enterasys Networks’ NetSight application, or the WebView application. Out‐of‐band management is provided through  the DB9 Console port connector on the front panel using a VT100 terminal or a VT100  terminal emulator. Switch Configuration Using WebView Enterasys Networks’ HTTP‐based Web management application (WebView) is an  intuitive web tool for simple management tasks. Switch Configuration Using CLI Commands The CLI commands enable you to perform more complete SecureStack A2 configuration  management tasks. For CLI command set information and how to configure the module, refer to the  SecureStack A2 Configuration Guide. Standards Compatibility The A2H254‐16 is fully compliant with the IEEE 802.3‐2002, 802.3ae‐2002, 802.1D‐1998,  and 802.1Q‐1998 standards. The SecureStack A2 provides IEEE 802.1D‐1998 Spanning  Tree Algorithm (STA) support to enhance the overall reliability of the network and  protect against “loop” conditions.  LANVIEW Diagnostic LEDs LANVIEW diagnostic LEDs serve as an important troubleshooting aid by providing an  easy way to observe the status of individual ports and overall network operations. Management ®  management  SecureStack A2 Installation Guide...
  • Page 24: Getting Help

    A description of your network environment (layout, cable type.) • Network load and frame size at the time of trouble, if known. • The device history (that is, have you returned the device before, is this a recurring  problem?) • Any previous Return Material Authorization (RMA) numbers. 1-6 Introduction http://www.enterasys.com/support 1-800-872-8440 (toll-free in U.S. and Canada) For the Enterasys Networks Support toll-free number in your country: http://www.enterasys.com/support/gtac-all.html support@enterasys.com To expedite your message, please type [SWITCHING] in the subject line.
  • Page 25: Chapter 2: Network Requirements

    Failure to do so will produce poor network performance. Note: The SecureStack A2 Configuration Guide and the Cabling Guide referred to in the following sections can be found on the Enterasys Networks World Wide Web site: http://www.enterasys.com/support/manuals For details about obtaining the manuals, refer to 10BASE-TX Twisted Pair Network When connecting a 10BASE‐TX segment to one of the fixed RJ45 ports (odd numbered ...
  • Page 26: 100Base-Tx Twisted Pair Network

    Category 5 UTP cabling with an impedance between 85 and 111 ohms for 100 Mbps operation. 1000BASE-T Twisted Pair Gigabit Ethernet Network The optional MGBIC‐02 supports 1000BASE‐T compliant RJ45 copper connections. When  connecting a 1000BASE‐T segment, use Category 5 UTP cabling. The device at the other  end of the twisted pair segment must meet IEEE 802.3‐2002 1000BASE‐T Gigabit Ethernet  network requirements for the devices to operate at 1000 Mbps.  When the A2 is in standalone mode (not stacked), the two stack ports 17 and 18 may be  user‐configured to serve as a standard switch ports allowing Gigabit uplink to the  network. 100BASE-FX Multimode Fiber-Optic Network The A2H254‐16 provides 8 ports that support 100 Mbps multimode fiber‐optic  connectivity using the fixed front‐panel MT‐RJ ports (even numbered ports 2‐16). The  MT‐RJ fixed front‐panel ports support 100BASE‐FX fiber‐optic cabling. The device at the  other end of the fiber‐optic segment must meet 100BASE‐FX Fast Ethernet network  requirements for the devices to operate at 100 Mbps. IEEE 802.3u 100BASE‐FX  characteristics for Multimode Fiber is a segment length of 412 meters (switched port) in ...
  • Page 27: 1000Base-Fx Fiber-Optic Network

    1000BASE-FX Fiber-Optic Network The Mini‐GBIC port sockets 19 and 20 on the A2H254‐16 enable you to vary the type of 1‐Gbps port connection. At the printing of this document there were five Mini‐GBICs  available that support fiber‐optic connections, as listed below, and one that supports a  copper connection as described in “1000BASE‐T Twisted Pair Gigabit Ethernet Network”  on page 2‐2:  • MGBIC‐LC01 for a 1000BASE‐SX compliant LC fiber‐optic multimode connection • MGBIC‐LC03 for a 1000BASE‐SX Long Haul LC fiber‐optic multimode connection • MGBIC‐LC09 for a 1000BASE‐LX compliant LC fiber‐optic single‐mode connection • MGBIC‐08 for a 1000BASE‐ELX compliant LC fiber‐optic single‐mode connection • MGBIC‐MT01 for a 1000BASE‐SX compliant MT‐RJ fiber‐optic single‐mode  connection The device at the other end of the fiber connection must meet the same Gigabit Ethernet  requirements for the connected devices to operate at 1‐Gigabit speed. 1000BASE-FX Fiber-Optic Network SecureStack A2 Installation Guide...
  • Page 28 1000BASE-FX Fiber-Optic Network 2-4 Network Requirements...
  • Page 29: Hardware Installation

    Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Read the Release Notes shipped with the switch to check for any exceptions to the supported features and operation documented in this guide. This chapter provides instructions to install the A2H254‐16. Follow the order of the  sections listed below to correctly install the switch.
  • Page 30: Considerations Prior To Installation

    A Phillips screwdriver is required to install the switch into a rack. Unpacking the Switch Unpack the switch as follows: Open the box and remove the packing material protecting the switch. Verify that the contents of the carton contains the items listed in Table 3‐1. Table 3-1 Contents of Switch Carton Item A2H254-16 Switch Mounting kit (two mounting brackets and eight M3x6-mm screws for rack mounting) Rubber feet with adhesive backing for installation on a flat surface AC power cord (The type of power cord is country dependent.)
  • Page 31: Installing Optional Mini-Gbics

    The Mini-GBIC and the device are sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to the Mini-GBIC or the switch. Always leave the Mini-GBIC in the antistatic bag or an equivalent antistatic container when not installed.
  • Page 32: Mini-Gbic With Rj45 Connector

    Installing Optional Mini-GBICs Installation To install a Mini‐GBIC that has an RJ45 connector, refer to Figure 3‐1; for a Mini‐GBIC  with an MT‐RJ connector, refer to Figure 3‐2; for a Mini‐GBIC with an LC connector, refer  to Figure 3‐3; and proceed as follows: Hold the Mini‐GBIC with the top side positioned as shown, and the 7‐pin edge  connector facing the port slot. Align the Mini‐GBIC with the port slot. If you are using the RJ45 Mini‐GBIC as in Figure 3‐1, be sure the release tab is in the  up position. Push the Mini‐GBIC into the port slot until the Mini‐GBIC “clicks” and locks into  place. Figure 3-1 1 SFP Slot 2 Mini-GBIC (MGBIC-02) 3-4 Hardware Installation Mini-GBIC with RJ45 Connector 3 Release tab 4 Link/Activity LED...
  • Page 33: Mini-Gbic With Mt-Rj Connector

    Figure 3-2 Mini-GBIC with MT-RJ Connector 1 SFP Slot 2 Mini-GBIC (MGBIC-MT01) Installing Optional Mini-GBICs 3 Release tab 4 Link/Activity LED SecureStack A2 Installation Guide...
  • Page 34: Removing The Mini-Gbic

    Mini-GBIC. This can damage the Mini-GBIC. The Mini-GBIC and its host switch are sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damaging the Mini-GBIC or host switch.
  • Page 35: Installing The Switch On A Flat Surface

    To remove a Mini‐GBIC from a port slot, refer back to Figure 3‐1, Figure 3‐2, or Figure 3‐3,  and proceed as follows: Attach your antistatic wrist strap (refer to the instructions in your antistatic wrist  strap package) before removing the Mini‐GBIC. Remove the cables connected to the Mini‐GBIC. Locate the release tab under the front end of the Mini‐GBIC. For the type of  Mini‐GBIC shown in: Figure 3‐1, push down on the metal release tab above the connector as far as it  will go to release the Mini‐GBIC from the port slot. b. Figure 3‐2, push in on the release tab as far as it will go to release the Mini‐GBIC  from the port slot. Figure 3‐3, pull out on the release tab to release the Mini‐GBIC from the port slot. Grasp the sides of the Mini‐GBIC and pull it straight out of the port slot. If storing or shipping a Mini‐GBIC, which has a fiber‐optic connector, insert its protective  dust cover to protect the ends of the fiber‐optic fibers from dust or contamination. Installing the Switch on a Flat Surface When installing the switch on a flat surface, the installation of the rubber feet is  recommended to prevent the switch from sliding on a flat surface. Installing the rubber  feet is optional if you are installing the switch in a rack. To install the rubber feet, proceed  to “Installing the Rubber Feet” instructions below. For instructions to rack mount the  switch, proceed to “Rack Mounting the Switch” on page 3‐9. Installing the Rubber Feet To install the rubber feet, refer to Figure 3‐4 and proceed as follows: Place the switch on its back on a sturdy flat surface to gain access to the bottom of the  chassis.  Remove the four rubber feet from their plastic bag in the shipping box. Locate the four marked locations on the bottom four corners of the chassis. Remove the protective strip from the back of one rubber foot and position it on a  marked location and press firmly into place. Repeat this procedure to install the  remaining three rubber feet in the other three locations.
  • Page 36: Guidelines For Flat Surface Installation

    2 Locations to install the rubber feet (four locations) Note: If a number of switches are being installed in a stack, repeat steps 1 through 4 to install the rubber feet on each switch before continuing with the installation. Guidelines for Flat Surface Installation Locate the switch within 152 cm (5 ft) of its power source and on a surface as shown in ...
  • Page 37: Rack Mounting The Switch

    Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch. Do not connect the switch to the AC power source until instructed to do so later in the installation process.
  • Page 38: Guidelines For Rackmount Installation

    Note: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch. Warning: Before rack-mounting the switch, ensure that the rack can support it without compromising stability.
  • Page 39: Connecting Stacking Cables

    “Connecting Stacking Cables” on page 3‐11. Otherwise, proceed to “Connecting AC  and RPS‐SYS Power” on page 3‐15. Connecting Stacking Cables The stack of switches can be connected in a closed loop or daisy chained. In a closed loop  all the switches are connected in sequence and the last switch in the stack is connected  back to the first switch. In a daisy chain configuration the cable that would return the  connection back to the first switch in a closed loop is not installed. The advantage of the  closed loop is redundancy, this configuration eliminates any single point of failure. Up to  eight switches can be stacked together and connected by standard UTP Category 5 or  better cables. The stacking cables allow the entire stack to operate with a single IP address. Figure 3‐8 shows an example of a four‐high stack connected in a closed loop  configuration. All STACK DOWN and STACK UP connectors are used in the installation.  The stacking cable connections are from the STACK DOWN connector of one switch to  the STACK UP connector of the next switch up in the stack. A stacking cable connection  from the STACK DOWN connector of the switch at the top of the stack to the STACK UP  connector at the bottom of the stack closes the loop. In a daisy chain configuration, one  cable connection is not made. Fastening the Switch to the Rack 2 Mounting screws (supplied by user) Connecting Stacking Cables SecureStack A2 Installation Guide 3-11...
  • Page 40: Configuring Switches In A Stack

    STACK UP connector STACK DOWN connector After connecting the cables to the stacking ports, proceed to “Configuring Switches in a  Stack” on page 3‐12 for instructions. Configuring Switches in a Stack The information in the following sections is important to understand A2 switch operation  and installations in a stack installation. About SecureStack A2 Switch Operation in a Stack The SecureStack A2 products are stackable switches that can be adapted and scaled to  help meet your network needs. These switches provide a management platform and  uplink to a network backbone for a stacked group of up to eight A2 switches.  3-12 Hardware Installation Stacking Cable Connections STACK UP connector at top of stack STACK DOWN connector at bottom of stack...
  • Page 41 Once installed in a stack, the switches behave and perform as a single switch. As such,  you can start with a single switch and add more switches as your network expands. You  can also mix different products in the same family in a single stack to provide a desired  combination of port types and functions to match the requirements of individual  applications. In all cases, a stack of switches performs as one large product, and is  managed as a single network entity. When switches are installed and connected as described back in “Connecting Stacking  Cables” on page 3‐11, the following occurs during initialization: • The switch that will manage the stack is automatically established and is referred to as  the Manager switch. • All other switches are established as Member switches in the stack.  • The hierarchy of the switches that will assume the function of backup manager is also  determined in case the current manager malfunctions, is powered down, or is  disconnected from the stack.  • The Console port on the manager switch remains active for out‐of‐band (local) switch  management, but the Console port on each member switch is deactivated. This  enables you to set the IP address and system password using a single Console port.  Now each switch can be configured locally using only the manager’s Console port, or  in‐band using a remote device and the CLI set of commands described in this section.  For procedures used for various types of connections to the Console port, refer to  “Connecting to Console Port for Local Management” on page 3‐18. Once a stack is created (more than one switch is interconnected), the following occurs: Switch (unit) IDs are arbitrarily assigned on a first‐come, first‐served basis. Switch IDs are saved against each module. Then, every time a board is power‐cycled,  it will initialize with the same switch ID. This is important for port‐specific  information (for example: fe.4.12 is the 12th Fast Ethernet port on switch number 4). The management election process uses the following precedence to assign a  management switch: Previously assigned/elected management switch b. Management assigned priority (values 1–15) Hardware preference level d. Highest MAC Address Configuring Switches in a Stack...
  • Page 42: Recommended Procedures For New And Existing Stacks

    The following procedures assume that all switches have a clean configuration from manufacturing. When adding a new switch to an already running stack, it is also assumed that the new switch is using the same firmware image version as other switches in the stack.
  • Page 43: Connecting Ac And Rps-Sys Power

    • Use clear config to clear config parameters without clearing stack switch IDs. This command WILL NOT clear stack parameters and avoids the process of re-numbering the stack. • Use clear config all when it is necessary to clear all config parameters, including stack switch IDs and switch priority values.
  • Page 44: Switch Rear View

    Note: If the CPU LED illuminates solid red, there was a critical failure. For more information about the LED indications and troubleshooting, refer to additional help, contact Enterasys Networks. Refer to details If the switch is a standalone switch, it will take approximately 30 seconds for the  switch to start up. If the switch is a stack Manager, it can take up to 3 minutes or more  to start up, depending on the number of Member switches in the stack. 3-16 Hardware Installation...
  • Page 45: C2Rps-Sys Redundant Power System

    Accessing the RPS Connector RPS coverplate Retaining screws to fasten plate Caution: To prevent damaging the switch, DO NOT connect a Power over Ethernet-compliant Redundant Power System (C2RPS-POE) to the redundant power supply connector. The switch is only compatible with the SecureStack C2RPS-SYS redundant power supply system.
  • Page 46: Stack Initialization Overview

    Note: When switches are connected in a stack configuration and all stacking cables are connected before powering up the switches, one switch in the stack will be automatically designated as the Manager of the stack and its Console port will remain active. All other switches will become Member switches and their Console ports will be deactivated.
  • Page 47: Connecting To An Ibm Or Compatible Device

    Using a DTE modem DB9 female‐to‐DB25 male cable, you can connect products equipped  with a DB9 DTE male console port to a Hayes compatible modem that supports  9600 baud. The cable used must connect the Console port Received Data, Pin 2 to the Transmitted  Data pin at the other end of the cable. The connection from the Console port Transmitted  Data, Pin 3 (must be connected) to the Received Data pin cable connection at the other end  of the cable. The DB9 Console port pin assignments are shown in Figure 3‐11. Figure 3-11 DB9 Male Console Port Pinout Assignments Connecting to an IBM or Compatible Device To connect an IBM PC or compatible device, running the VT terminal emulation, to an  Enterasys switch Console port (Figure 3‐12), proceed as follows: Connect the DB9 female connector at one end of the cable (not supplied) to the  Console port on the Enterasys switch. (If there is a switch designated as the Manager,  connect to its Console port.) Plug the DB9 female connector at the other end of cable into the communications port  on the PC. Turn on the PC and configure your VT emulation package with the following  parameters: Parameter Mode Transmit Bits Parity Stop Bit...
  • Page 48: Connecting To A Vt Series Terminal

    Connecting to Console Port for Local Management When these parameters are set, the Startup screen will display. Proceed to “Connecting to  the Network” on page 3‐23. Figure 3-12 1 DB9 female connector 2 Serial interface cable 3 DB9 male Console port connector Connecting to a VT Series Terminal To connect a VT Series terminal to an Enterasys switch Console port (Figure 3‐13), use a  UTP serial interface cable terminated with a DB9 female connector and a DB25 female  connector and proceed as follows: Connect the DB9 female connector at one end of cable to the Console port DB9 male  connector on the Enterasys switch. (If there is a switch designated as the Manager,  connect to its Console port.) Plug the DB25 female connector at the other end of the cable into the port labeled  COMM on the VT terminal. Turn on the terminal and access the Setup Directory. Set the following parameters on ...
  • Page 49: Connecting To A Modem

    When these parameters are set, the Startup screen will display. Proceed to “Connecting to  the Network” on page 3‐23. Figure 3-13 Connecting a VT Series Terminal 1 DB9 female connector 2 Serial interface cable 3 DB9 male Console port connector Connecting to a Modem To connect a modem to an Enterasys Networks switch modem port (Figure 3‐14), use a  UTP cable terminated with a DB9 female connector and a DB25 male connector, and  proceed as follows: Connect the DB9 female connector at one end of the cable to the Console port DB9  connector on the Enterasys switch. (If there is a switch designated as the Manager,  connect to its Console port.) Plug the DB25 male connector at the other end of the cable into the modem  communications port. Turn on the modem and make sure the remote modem is ON. With your PC connected to the remote modem, configure your VT emulation package  with the following parameters: Parameter Mode...
  • Page 50: Connecting To A Modem

    Connecting to Console Port for Local Management When these parameters are set, the Startup screen will display. If the switches are in a  stacked configuration, proceed to “Connecting to the Network” on page 3‐23. Figure 3-14 1 DB9 female cable connector 2 Serial interface cable 3 DB9 male Console port 4 DB25 male connector 3-22 Hardware Installation Connecting to a Modem Æ Å Ä 5 Local modem 6 Remote modem 7 PC with VT emulation application Ã...
  • Page 51: Connecting To The Network

    MT‐RJ fixed front panel ports of the A2H254‐16 to the network or other devices. Each  fiber‐optic link consists of two fiber‐optic strands within the cable: Transmit (TX) and  Receive (RX). The transmit strand from an A2H254‐16 port connects to the receive port of a fiber‐optic  100BASE‐FX Ethernet device at the other end of the segment. The receive strand of the  applicable MT‐RJ port on the switch connects to the transmit port of the fiber‐optic  100BASE‐FX Ethernet device. Note: An odd number of crossovers (preferably one) must be maintained between devices so that the transmit port is connected to the receive port of the other device and vice versa. To connect a fiber‐optic cable segment to the switch, refer to Figure 3‐15 and proceed as  follows: Remove the protective covers (not shown) from the MT‐RJ front panel connector and ...
  • Page 52: Connecting A Fiber-Optic Cable Segment To Mt-Rj Port

    Connecting to the Network Caution: Do not touch the ends of the fiber-optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants. Contamination of cable ends causes problems in data transmissions. If the ends of the fiber-optic strands become contaminated, use a canned duster to blow the surfaces clean.
  • Page 53: Connecting Fiber-Optic Cables To Mt-Rj Mini-Gbic Ports

    Solche Hilfsmittel erhöhen die Gefahr von Sehschäden. Wenn sie den optischen Port überprüfen möchten stellen Sie sicher, dass die Komponente von der Spannungsversorgung getrennt ist. This section contains the procedures for connecting a 1000BASE‐SX multimode fiber‐optic  segment from the network or other device to an MT‐RJ port connector in a Mini‐GBIC  (MGBIC‐MT01). Each fiber‐optic link consists of two fiber‐optic strands within the cable: • Transmit (TX) • Receive (RX) The transmit strand from the MT‐RJ port connects to the receive port of a fiber‐optic  Gigabit Ethernet device at the other end of the segment. The receive strand of the  applicable MT‐RJ port connects to the transmit port of the fiber‐optic Gigabit Ethernet  switch. Enterasys Networks recommends labeling fiber‐optic cables to indicate receive and  transmit ends. Many cables are pre‐labeled, providing matching labels or tapes at both  ends of each strand of cable. Connecting to the Network SecureStack A2 Installation Guide 3-25...
  • Page 54 Connecting to the Network To connect an MT‐RJ cable to a fixed MT‐RJ connector of a Mini‐GBIC: Remove the protective covers from the Mini‐GBIC MT‐RJ fiber‐optic port and from  the connectors on each end of the cable. Note: Leave the protective covers in place when the connectors are not in use to prevent contamination. Caution: Do not touch the ends of the fiber-optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants.
  • Page 55: Connecting Fiber-Optic Cables To Lc Mini-Gbic Ports

    Connecting Fiber-Optic Cables to LC Mini-GBIC Ports Warning: Fiber-optic Mini-GBICs use Class 1 lasers. Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.
  • Page 56 Connecting to the Network To connect an LC cable connector to a fixed LC connector of a Mini‐GBIC: Caution: Do not touch the ends of the fiber-optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants. Contamination of cable ends causes problems in data transmissions. If the ends of the fiber-optic strands become contaminated, use a canned duster to blow the surfaces clean.
  • Page 57: Connecting Utp Cables To Rj45 Ports

    Note: All RJ45 ports support Category 5 Unshielded Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category 3 cable may be used if the connection is going to be used only for 10 Mbps. To connect twisted pair segments to the switch, refer to Figure 3‐16 and proceed as  follows: Ensure that the device to be connected at the other end of the segment is ...
  • Page 58 Connecting to the Network Verify that a link exists by checking that the Link/Activity LED is ON (solid green or  blinking green). If the Link/Activity LED is OFF, perform the following steps until it is  Verify that the cabling being used is Category 5 or better with an impedance  between 85 and 111 ohms with a maximum length of 100 meters (328 feet).  b. Verify that the device at the other end of the twisted pair segment is on and  properly connected to the segment. Verify that the RJ45 connectors on the twisted pair segment have the proper  pinouts and check the cable for continuity. Typically, a crossover cable is used  between hub devices. A straight‐through cable is used to connect between  switches or hub devices and an end user (computer). Refer to Figure 3‐17 and  Figure 3‐18 for four‐wire RJ45 connections. Refer to Figure 3‐19 and Figure 3‐20  for eight‐wire RJ45 connections. d. Ensure that the twisted pair connection meets the dB loss and cable specifications  outlined in the Cabling Guide. Refer to “Related Documents”  on page xiv for  information on obtaining this document. If a link is not established, contact Enterasys Networks. Refer to “Getting Help” on  page 1‐6 for details. Repeat all steps above until all connections have been made. 3-30 Hardware Installation...
  • Page 59: Four-Wire Crossover Cable Rj45 Pinouts For 10/100Base-Tx

    Figure 3-17 Four-Wire Crossover Cable RJ45 Pinouts for 10/100BASE-TX À à 1 RJ45 switch port 2 Other device port Figure 3-18 Four-Wire Straight-Through Cable RJ45 Pinouts for 10/100BASE-TX À à 1 RJ45 switch port 2 Other device port  3 RJ45-to-RJ45 crossover cable 4 RX+/RX- and TX+/TX-connections These connections must share a common color pair.
  • Page 60: Eight-Wire Crossover Cable Rj45 Pinouts For 10/100/1000Base-Tx

    Connecting to the Network Figure 3-19 1 RJ45 device port 2 Other device port Figure 3-20 1000BASE-TX 1 RJ45 device port 2 Other device port 3-32 Hardware Installation Eight-Wire Crossover Cable RJ45 Pinouts for 10/100/1000BASE-TX À Â 3 RJ45-to-RJ45 crossover cable Eight-Wire Straight-Through Cable RJ45 Pinouts for 10/100/ À...
  • Page 61: Completing The Installation

    Completing the Installation After installing the switch and making the connections to the network, access the switch  management, as described below. Initial Logon to Switch Management To initially access switch management from your local PC, terminal, or modem  connection, proceed as follows at the displayed startup screen: Enter ro (Read‐Only), rw (Read‐Write), or admin (superuser) for Username. At the Password prompt, press Enter (RETURN).  For details on how to configure the switch using the command line interface, refer to  the SecureStack A2 Configuration Guide. The CLI commands enable you to set a new  password and perform more involved management configurations on the switch.  One of many capabilities is to reconfigure the stack, reassigning the Manager function  to another switch and configuring the order of Member switches that will take over  the stack management functions in case the operating Manager is powered down,  malfunctions, or is removed from the stack.  After the initial configuration, you can also use WebView (Enterasys Networks’  embedded web server) for configuration and management tasks.  All the guides associated with the switch are available online at: http://www.enterasys.com/support/manuals Once you are confident that the installation is successful, route and secure your cables. If  you require assistance, contact Enterasys Networks using one of the methods described in  “Getting Help” on page 1‐6. Completing the Installation SecureStack A2 Installation Guide 3-33...
  • Page 62 Completing the Installation 3-34 Hardware Installation...
  • Page 63: Chapter 4: Troubleshooting

    This chapter provides information concerning the following: For information about... Using LANVIEW Troubleshooting Checklist Using the Reset Password Button This device contains a battery that is not considered a user replaceable part. If the battery  needs to be replaced, contact customer service for repair. Caution: There is a risk of explosion if the battery is replaced with an incorrect type. A used battery may be safely disposed in a municipal waste stream. Precaucion: Hay riesgo de explosion si la bateria se reemplaza con el typo incorrecto.
  • Page 64: Using Lanview

    Using LANVIEW Using LANVIEW The A2H254‐16 supports the Enterasys Networks built‐in LANVIEW LED visual  diagnostic and status monitoring system. The LANVIEW LEDs on the A2H254‐16 are  located as shown in Figure 4‐1. These LEDs allow you to quickly observe network status  for diagnosing switch and network problems. Figure 4-1 Recessed Password Reset Button Redundant Power Supply Active Unit selected as Stack Manager CPU and Power Indicator Note: The terms flashing, blinking, and solid used in Flashing: LED is flashing randomly.
  • Page 65: Lanview Leds

    3. If the SecureStack A2 still does not power up, the system may have a fatal error. Contact Enterasys Networks for technical support. If the LED remains red for several minutes, the system may have a fatal error.
  • Page 66 1. Make sure the switch connected to the stackup connector is powered on. 2. Replace cable with a known good one. 3. If the problem still exists, contact Enterasys Networks for technical support. None. 1. Make sure the switch connected to the stackdown connector is powered on.
  • Page 67 AC power source. 2. Replace the power cord with a known good one. 3. If the problem persists, contact Enterasys Networks for technical support. None. Power on remote device. Use CLI to enable port.
  • Page 68: Troubleshooting Checklist

    Replace the power cord with a known good one. Connect to the console port and type “show switch”. If a code mismatch is the cause, the output of the above command will show “code version mismatch”. Disconnect the switch from the stack and load the necessary code to match the stack master.
  • Page 69: Troubleshooting Checklist

    Refer to the SecureStack A2 Configuration Guide for the IP address assignment procedure. This is normal if the switch is a Member in a stack. If operating as a standalone switch or as the Manager in a stack, enable the port.
  • Page 70: Using The Reset Password Button

    Using the Reset Password Button Using the Reset Password Button If you forget the SecureStack A2 login password, use the Reset Password button as  described in the following procedure.  Figure 4-2 1 Reset Password button To reset the SecureStack A2 password, refer to Figure 4‐2 and proceed as follows: Note: Notify the system manager before changing the password. Press‐and‐hold the Reset Password button while the switch is operational. This  change of the login password to the default password will be indicated via Local  Management CLI only. This information will not show up in a Telnet session. Logon to switch management. You can now logon to the switch via the Console port  and assign a new password using the command line interface (CLI).  To access switch management from your local PC, terminal, or modem connection,  refer to the SecureStack A2 Configuration Guide for instructions on how to log in and  enter a new password. The guide is available online under the S category for  Securestack at: http://www.enterasys.com/support/manuals If you require assistance, contact Enterasys Networks using one of the methods described  in “Getting Help” on page 1‐6.
  • Page 71: Switch Specifications

    Console Port Pinout Assignments Regulatory Compliance Enterasys Networks reserves the right to change the specifications at any time without  notice. Switch Specifications Table A‐1 provides the I/O ports, processors and memory, physical, and environmental  specifications for the A2H254‐16. Table A-1 A2H254-16 Switch Specifications Item RJ45 odd numbered ports 1 through 15 MT-RJ even numbered ports 2 through 16 RJ45 ports 17 and 18 SFP ports 19 and 20...
  • Page 72 Switch Specifications Table A-1 A2H254-16 Switch Specifications (continued) Item Dimensions Approximate Weight Heat Dissipation (maximum) Power Amperage Power Consumption Processors/Memory Processor Dynamic Random Access Memory (DRAM) FLASH Memory Physical Predicted hours for Mean Time Between Failures (MTBF) Environmental Operating Temperature...
  • Page 73: Mini-Gbic Input/Output Specifications

    Mini-GBIC Input/Output Specifications The Mini‐Gigabit Ethernet Card (Mini‐GBIC) port interface slots can support 1‐Gbps  fiber‐optic connections as described in Table A‐2. The optional Mini‐GBICs are hot  swappable. Table A-2 Mini-GBIC Input/Output Port Specifications Item MGBIC-LC01 MGBIC-LC03 MGBIC-LC09 MGBIC-MT01 MGBIC-08 MGBIC-02 Specification Provides one LC fiber-optic multimode port that is compliant with the 1000BASE-SX standard LC connector. Provides one LC Long Haul (up to 2 KM) fiber-optic multimode port that is compliant with the 1000BASE-SX standard LC duplex style connector.
  • Page 74: Gigabit Ethernet Specifications

    Gigabit Ethernet Specifications Gigabit Ethernet Specifications The following specifications for the Mini‐GBICs shown in Table A‐3 through Table A‐11  meet or exceed the IEEE 802.3z‐1998 standard. MGBIC-LC01/MGBIC-MT01 Specifications (1000BASE-SX) Table A-3 MGBIC-LC01/MGBIC-MT01 Optical Specifications Item Transmit Power (minimum) Receive Sensitivity Link Power Budget Table A-4 MGBIC-LC01/MGBIC-MT01 Operating Range Item 62.5 µm MMF 62.5 µm MMF 50 µm MMF 50 µm MMF MGBIC-LC03 Specifications (1000BASE-SX) Table A-5 MGBIC-LC03 Optical Specifications...
  • Page 75: Mgbic-Lc09 Specifications (1000Base-Lx

    Table A-6 MGBIC-LC03 Operating Range Item 62.5 µm MMF 50 µm MMF MGBIC-LC09 Specifications (1000BASE-LX) Table A-7 MGBIC-LC09 Optical Specifications Item Transmit Power (minimum) Receive Sensitivity Link Power Budget Table A-8 MGBIC-LC09 Operating Range Item 62.5 µm MMF 50 µm MMF 50 µm MMF 10 µm SMF Modal Bandwidth @ 1310 nm...
  • Page 76: Mgbic-08 Specifications (1000Base-Elx

    Gigabit Ethernet Specifications MGBIC-08 Specifications (1000BASE-ELX) Table A-9 MGBIC-08 Optical Specifications Item Transmit Power (minimum) Receive Sensitivity Maximum Input Power Link Power Budget (Full Duplex Only) 1. The maximum drive distance (up to 70 km) depends on the quality of the installed single-mode fiber-optic cable segment.
  • Page 77: Console Port Pinout Assignments

    Console Port Pinout Assignments The Console port is a DB9 serial communications port for local access to Local  Management. Refer to Figure A‐1 for the Console port pin assignments. Figure A-1 Pin 2, Received Data (input) Pin 3, Transmitted Data (output) Regulatory Compliance The A2H254‐16 meets the safety and electromagnetic compatibility (EMC) requirements  listed in Table A‐12: Table A-12 Compliance Standards Regulatory Compliance Safety Electromagnetic Compatibility (EMI) (Class A) Console Port Pinout Assignments Standards UL 60950, CSA 60950, EN 60950, EN 60825, IEC 60950, EN 60825, 21 CFR 1040.10 47 CFR Parts 2 and 15, CSA C108.8, EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3, AS/NZS...
  • Page 78 Regulatory Compliance A-8 Specifications...
  • Page 79 Enterasys contacting Fiber budget Installation connecting to the network in a rack new stack new switch in existing stack stacking cables Installation site what is needed at the Installing Optional Mini-GBICs LANVIEW Diagnostic LEDs introduction to LANVIEW LEDs Link LEDs...
  • Page 80 Stack Member automatic selection of 3-31 Stack Operation member switch selection 3-32 Stack System installation of a new switch in existing stack installation of new Stacking cables installation of Standalone Switches specifications for Standards compatibility Switch overview of...

Table of Contents