Set Rmon Alarm Status - Enterasys N Standalone (NSA) Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

11.2.4.9

set rmon alarm status

Use this command to enable an RMON alarm entry. An alarm is a notification that a statistical
sample of a monitored variable has crossed a configured threshold.
set rmon alarm status index enable
NOTE:
An RMON alarm entry can be created using this command, configured using
set rmon alarm properties
the
command. An RMON alarm entry can be created and configured at the same time by
specifying an unused index with the set properties command.
Syntax Description
index
enable
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to enable RMON alarm entry 3:
Matrix(rw)->
command
Specifies an index number for this entry. Maximum
number or entries is 50. Maximum value is 65535.
Enables this alarm entry.
set rmon alarm status 3 enable
Logging And Network Management Command Set
(Section
11.2.4.8), then enabled using this
Matrix NSA Series Configuration Guide