3.2.2.4

set cdp interval

Use this command to set the message interval frequency (in seconds) of the CDP discovery
protocol.
set cdp interval frequency
Syntax Description
frequency
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the CDP interval frequency to 15 seconds:
Matrix(rw)->set cdp interval 15
Specifies the transmit frequency of CDP messages in
seconds.Valid values are from 5 to 900 seconds.
Matrix NSA Series Configuration Guide
Discovery Protocols Command Set
Enterasys Discovery Protocol
3-9