rmon alarm
c e s
Syntax
Parameters
Default
Command Modes
1254
|
Remote Monitoring (RMON)
rmon hc-alarm
show rmon
show rmon alarms
show rmon events
show rmon hc-alarm
show rmon history
show rmon log
show rmon statistics
Set an alarm on any MIB object.
rmon alarm number variable interval {delta | absolute} rising-threshold value
event-number falling-threshold value event-number [owner string]
To disable the alarm, use the no rmon alarm number command.
number
variable
interval
delta
absolute
rising-threshold value
event-number
falling-threshold value
event-number
owner string
owner
CONFIGURATION
Enter the alarm integer number from 1 to 65535. The value must be unique
in the RMON Alarm Table.
The MIB object to monitor. The variable must be in the SNMP OID format,
for example, 1.3.6.1.2.1.1.3 The object type must be a 32 bit integer.
Time, in seconds, the alarm monitors the MIB variables; this is the
alarmSampleType in the RMON Alarm table.
Range: 5 to 3600 seconds
delta
Enter the keyword
to test the change between MIB variables. This is
the alarmSampleType in the RMON Alarm table.
absolute
Enter the keyword
alarmSampleType in the RMON Alarm table.
rising-threshold
Enter the keyword
rising-threshold alarm is either triggered or reset. Then enter the
event-number to trigger when the rising threshold exceeds its limit. This
value is the same as the alarmRisingEventIndex or alarmTable of the RMON
MIB. If there is no corresponding rising-threshold event, the value is zero.
falling-threshold
Enter the keyword
falling-threshold alarm is either triggered or reset. Then enter the
event-number to trigger when the falling threshold exceeds its limit.
This value is the same as the alarmFallingEventIndex or the alarmTable of
the RMON MIB. If there is no corresponding falling-threshold event, the
value is zero.
(OPTIONAL) Enter the keyword
specify an owner for the alarm. This is the alarmOwner object in the
alarmTable of the RMON MIB.
to test each MIB variable directly. This is the
followed by the value (32bit) the
followed by the value (32bit) the
owner
followed by the owner name to

Advertisement

loading