Download Print this page

Dell Force10 TeraScale E Series Reference Manual page 1340

Ftos command line, ftos 8.4.2.7

Advertisement

Command
History
Usage
Information
protocol-tunnel rate-limit
c e s
Syntax
Parameters
Defaults
Command Modes
Command
History
Example
Related
Commands
show protocol-tunnel
c e s
Syntax
Parameters
Defaults
Command Modes
1340
|
Service Provider Bridging
Version 7.4.1.0
Introduced
FTOS must have the default CAM profile with the default microcode before you enable L2PT.
Enable traffic rate limiting per box.
protocol-tunnel rate-limit rate
To reset the rate limit to the default, use the no protocol-tunnel rate-limit rate command.
rate
Enter the rate in frames per second.
Range: 75 to 3000
Default: 75
75 Frames per second
CONFIGURATION
Version 8.2.1.0
Introduced on the C-Series, E-Series Terascale, and E-Series ExaScale. Maximum rate
limit on E-Series reduced from 4000 to 3000.
Version 7.4.1.0
Introduced
Figure 52-2. protocol-tunnel rate-limit Command Example
FTOS#
FTOS#conf
FTOS(conf)#protocol-tunnel rate-limit 1000
FTOS(conf)#
show protocol-tunnel
show running-config
Display protocol tunnel information for all or a specified VLAN-Stack VLAN.
show protocol-tunnel [vlan vlan-id]
vlan vlan-id
(OPTIONAL) Enter the keyword
for the one VLAN.
Range: 1 to 4094
No default values or behavior
EXEC
Display tunneling information for all VLANs
Display the current configuration.
vlan
followed by the VLAN ID to display information

Advertisement

loading