Important Points to Remember
show snmp
c e s
Syntax
Command Modes
Command
History
Example
Related
Commands
1356
|
SNMP and Syslog
Typically, 5-second timeout and 3-second retry values on an SNMP server are sufficient for both
LAN and WAN applications. If you experience a timeout with these values, the recommended best
practice on Dell Force10 switches (to accommodate their high port density) is to increase the
timeout and retry values on your SNMP server to the following:
— SNMP Timeout—greater than 3 seconds
— SNMP Retry count—greater than 2 seconds
If you want to query an E-Series switch using SNMP v1/v2/v3 with an IPv6 address, configure the
IPv6 address on a non-management port on the switch.
If you want to send SNMP v1/v2/v3 traps from an E-Series using an IPv6 address, use a
non-management port.
SNMP v3 informs are not currently supported with IPv6 addresses.
If you are using ACLs in SNMP v3 configuration, group ACL overrides user ACL if the user is
part of that group.
SNMP operations are not supported on a VLAN.
Display the status of SNMP network elements.
show snmp
EXEC
EXEC Privilege
Version 7.6.1.0
Support added for S-Series
Version 7.5.1.0
Support added for C-Series
E-Series legacy command
Figure 54-1. show snmp Command Example
FTOS#show snmp
32685 SNMP packets input
0 Bad SNMP version errors
0 Unknown community name
0 Illegal operation for community name supplied
0 Encoding errors
96988 Number of requested variables
0 Number of altered variables
31681 Get-request PDUs
968 Get-next PDUs
0 Set-request PDUs
61727 SNMP packets output
0 Too big errors (Maximum packet size 1500)
9 No such name errors
0 Bad values errors
0 General errors
32649 Response PDUs
29078 Trap PDUs
FTOS#