Setup Syslog - Fujitsu ETERNUS DX60 S3 User Manual

Disk storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Chapter 1 System Management
1.8 Network Management
1.8.13

Setup Syslog

This function sets up external servers (Syslog server) for sending logs of events that are detected by the
ETERNUS DX.
Up to two Syslog servers can be registered.
The following events are sent as Syslogs:
All the notification target events that are configured using the procedure in
Notification" (page 144)
Logins and logouts from ETERNUS Web GUI and ETERNUS CLI
Select whether to send ("on") or not send ("off") Syslogs for each ETERNUS DX.
Confirm that the Syslog has been successfully sent to the Syslog server by logging in and out from
ETERNUS Web GUI or ETERNUS CLI and performing a transmission test to the Syslog server.
Even if a communication error occurs between the ETERNUS DX and the Syslog server, the Syslog is not
sent again.
Use the procedure in
Syslog.
Syslogs are sent to both Syslog servers at the same time.
If the wrong Syslog settings information is specified, an error message appears during configuration.
The parameter settings for Syslog remain even when the "Send Log" setting is changed to "off".
For details on the parameters for this function, refer to
For the factory default settings for this function, refer to
The procedure to set up the Syslog is as follows:
Procedure
1
Click [Setup Syslog] in [Action].
"1.9.1 Setup Event Notification" (page 144)
132
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
"1.9.1 Setup Event
for specifying events to be notified as a
"A.1.7.11 Setup Syslog" (page
"Appendix B Setup Syslog" (page
720).
982).
P2X0-1270-13ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents