Fujitsu ETERNUS DX60 S3 User Manual page 133

Disk storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Chapter 1 System Management
1.8 Network Management
2
Specify the parameters.
The main setting items are as follows.
Syslog Server
Send Log
Domain Name / IP Address
Port No.
LAN Port
An error screen appears if the specified IP address of the Syslog server conflicts with the internal IP
address of the ETERNUS DX. If this occurs, check the parameter settings.
Up to two Syslog servers can be configured. When configuring a second Syslog server, specify the
required parameters in "Syslog Server2".
3
Click the [Set] button.
 A confirmation screen appears.
4
Click the [OK] button.
 Setting of the Syslog starts.
5
Click the [Done] button to return to the [Network] screen.
133
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
End of procedure
P2X0-1270-13ENZ0