Chapter 4 Connectivity Management
4.3 CA Port Group Management
The procedure to change the port mode is as follows:
Procedure
1
Click [Modify Port Mode] in [Action].
2
Select the port mode to be changed over to.
The main setting item is as follows.
Port List
Port Mode (After)
If the specified FC-Initiator port is configured in Storage Migration path, an error screen appears. If
this occurs, check the parameter settings.
3
Click the [Set] button.
 A confirmation screen appears.
"RA" and "CA/RA" are displayed as options only for the models that support REC.
4
Click the [OK] button.
 Port mode changeover starts.
5
Click the [Done] button to return to the [CA Port] screen.
461
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
End of procedure