Miscellaneous Option Cards

This section contains technical information and SecureSync Web UI procedures
pertaining to option cards that do not fall into other categories, e.g. cards that
serve as signal relays.
SecureSync 2400 User Manual
Contract
tab of the
Contract
tab of the GB PTP Edit window, make the following set-
Min Sync
Interval: The minimum value of Sync interval granted by
the Master Clock. In packets per second.
Max Sync
Duration: The maximum value of Sync interval granted by
the Master Clock. In seconds.
Min Announce
Interval: The minimum value of the Announce interval
granted by the Master Clock. In packets per second.
Max Announce
Duration: The maximum value of the Announce inter-
val granted by the Master Clock. In seconds.
Min Delay_Req
Interval: In packets per second.
Max Delay_Req
Duration: In seconds.
Max
Slaves: The maximum number of slaves to be served. The 1204-
32 module can serve up to 4000 slaves (unicast contracts).