Safran SecureSync 2400 User Manual page 495

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

The Status window displays the following settings:
Reference
table for this particular input reference.
Validity: [TIME, PPS] Indicates the validity of the Time input and the PPS
input. If the input signal is valid the indicator will be green. If the signal is not
valid, the indicator will be orange.
Format: Used to configure the formatting of the four available HAVE
QUICK outputs. The available output formats are as follows:
STANAG 4246 HQ I
STANAG 4246 HQ II
STANAG 4430 STM
STANAG 4430 Ext HQ
ICD-GPS-060A BCD
ICD-GPS-060A HQ
DOD-STD-1399 BCD
Timescale: Used to select the time base for the incoming time code data.
The entered Timescale is used by the system to convert the time in the
incoming data stream to UTC time for use by the System Time. The avail-
able choices are:
UTC: Coordinated Universal Time ("temps universel coordonné"), also
referred to as ZULU time
TAI: Temps Atomique International
SecureSync 2400 User Manual
ID: Indicates the letters used in the Input Reference Priority
APPENDIX