Figure 5-64:
Figure 5-65:
5.2.7.5

Event Broadcast [1204-23]

The Event Broadcast Module (RS-232) provides a BNC connection for an Event
Trigger Input and a RS-232 connector for an ASCII message output.
When the defined signal edge is detected on the Event Input BNC Connector, an
ASCII message is created containing the current time.
ASCII messages are stored in a Message Buffer. The message buffer can store
512 entries before overflowing. Messages may be lost if the buffer overflows.
Messages can be output in one of two ways:
If the
put immediately through the RS-232 Output port. If another event is
SecureSync 2400 User Manual
Model 1204-2E option card rear plate
Location of jumper switches
Mode
is set to Broadcast, messages in the
Message Buffer
will be out-