Note:
number that input or output 0. Additional inputs or outputs will be
numbered 1 or above.
The IRIG output Edit window offers the following configuration fields:
Signature
present. This function allows the modulation to stop under certain
conditions; see also
Format: Defines the desired IRIG output formatting. Available options
include: IRIG A, B, G, NASA-36, IRIG E (100 Hz or 1kHz)
Modulation: Changes the type of output signal modulation:
IRIG AM
put is determined by the value entered in the "Amplitude" field.
IRIG DCLS
SecureSync 2400 User Manual
If you have only one input or output of any type, NetClock will
Control: Used to control when the IRIG modulation will be
"Signature Control" on
is an amplitude modulated output. The amplitude of the out-
is a TTL modulated output.
page 183.