APPENDIX
HAVE QUICK Input: Status Window
To view the current settings of the HAVE QUICK Input (also referred to as 'Refer-
ence'), go to its Status window. For instructions, see:
figuration Settings" on
The Web UI list entry for this card is: HAVE QUICK In/Out.
The input is named: HQ Input [number].
478
STANAG 4246 HQ I
STANAG 4246 HQ II
STANAG 4372 HQ II A
STANAG 4430 STM
STANAG 4430 Ext HQ
ICD-GPS-060A BCD
ICD-GPS-060A HQ
DOD-STD-1399 BCD
Timescale: Used to select the time base for the incoming time code data.
The entered Timescale is used by the system to convert the time in the
incoming data stream to UTC time for use by the System Time. The avail-
able choices are:
UTC: Coordinated Universal Time ("temps universel coordonné"), also
referred to as ZULU time
TAI: Temps Atomique International
GPS: The raw GPS time as transmitted by the GNSS satellites (as of
22-August-2023, this is 18 seconds ahead of UTC time)
Offset: Provides the ability to account for HAVE QUICK cable delays
or other latencies in the HAVE QUICK outputs. The Offset values are
entered in nanoseconds (ns). The available Offset range is –500 to
+500 ms.