Safran SecureSync 2400 User Manual page 528

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

APPENDIX
Module Information
Configuration — General Steps
In order to operate properly as a Master Clock, SecureSync must be syn-
chronized to a non-PTP reference. Confirm that the chosen reference transmits
the following information (as reported by the Time Properties on the PTP Status
page, under the Advanced tab):
If the reference does not transmit this information, it must be provided by the
user in order for the Master Clock to function properly.
The built-in GNSS reference provides all information needed with no user inter-
vention.
512
PPS
Offset: See
Software
Version: Version number of embedded software
Hardware Version:
Version number
Ensure that SecureSync's PTP port is connected to the network (check the
Link Status in the
PTP Status/Network
Ensure the PTP port speed is 100 Mb/s (see:
tab >
Port
Speed).
Be sure that valid time and 1PPS references are currently selected (go to
MANAGEMENT/OTHER/Time
The proper TAI or UTC time (including the current year)
The current TAI to UTC offset (required even if the reference's time is in
TAI)
Pending leap second information at least a day in advance.
Note:
Peer-to-Peer Delay Mechanism is only applic-
able on networks equipped with Transparent
Clocks (switches/routers IEEE 1588 compatible).
Peer-to-Peer Delay Mechanism is not supported in
Unicast transmission mode.
"Advanced tab settings" on
page).
Management).
page 504.
PTP Status
page >
Advanced