APPENDIX
1PPS Output: Status Window
To view the current settings of a 1PPS Output, go to its Status window. For
instructions, see:
The Web UI list entries for these option cards are:
The Status window displays the following settings:
390
Signature Control:
Used to control when the 1PPS output signal will be
present. See
"Signature Control" on
Offset:
Used to account for 1PPS cable delays or other latencies in the 1PPS
output. The Offset value is entered and displayed in nanoseconds (ns). The
available Offset range is -500 to +500 ms.
Edge:
The operator can select if the output signal is a positive (reference
on the rising edge) or a negative (reference on the falling edge) pulse.
Pulse Width:
Configures the Pulse Width of the 1PPS output. The Pulse
Width is entered and displayed in nanoseconds (ns). The default Pulse
Width is 200 milliseconds.
"Viewing Input/Output Configuration Settings" on
1PPS OUT, 4-BNC
1PPS OUT, 10V
1PPS OUT, RS-485
1PPS OUT, Fiber
Signature Control:
Displays the current configuration of Signature Control;
see
"Signature Control" on
Frequency:
Indicates the configured frequency of the 1PPS output signal.
Offset:
Displays the configured Offset (to account for cable delays or other
latencies).