2.9  Connecting Supply Power
A DC power connector to attach DC power to SecureSync is included in the ancil-
lary kit provided with the equipment. A cable of 6 feet or less, using 16AWG wire,
with adequate insulation for the DC voltage source should be used with this con-
nector. The cable clamp provided with the DC power plug for strain relief of the
DC power input cable should be used when DC power is connected to
SecureSync.
DC power- +12 V and +24/48 V identification
To eliminate confusion, the two different voltages for DC power use different con-
nectors. The DC connectors are identical between the fixed or hot-swappable ver-
sions.
The +12 V
above the input or on the body of the power supply module (for Hot Swap mod-
els). The connector is keyed to prevent incorrect insertion.
The +24/48 V
either above the input or on the body of the power supply sled (for Hot Swap
models). This connector is also keyed to prevent incorrect insertion.
DC power connectors
SecureSync units can be ordered in a DC version that includes the following DC
receptacle on the back panel: DC Receptacle , 2-pin, chassis mount: Amphenol
97-3102A-10SL-4P(946); (Safran P/N J240R-0021-000G) or DC Receptacle , 3-
pin, chassis mount: Amphenol 97- 3102A- 10SL- 3P (946) (Safran P/N J240R-
0032-012F):
Figure 2-3:
54
DANGER!
GROUNDING: SecureSync is earth grounded through the
24/48 V
3-Pin power connector. Ensure that the unit is connected
DC
to a DC power source that is connected to earth ground via the
grounding pin C of the SecureSync DC power plug supplied in the
ancillary kit.
power supply uses a 2-pin connector and has a 12 V label, either
DC
power supply uses a 3-pin connector and has a 24/48 V label,
DC
DC Plug, 2-Pin and DC Plug, 3-Pin
CHAPTER
2
SecureSync 2400 User Manual Rev. 5.2