Configuring A Gpio Output - Safran SecureSync 2400 User Manual

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

2.20  Configuring Outputs
To view the current settings of the ASCII Input (also referred to as 'Reference'),
go to its Status window. For instructions, see:
figuration Settings" on
2.20.5
Configuring a GPIO Output
A GPIO Output is available through the BNC and/or Multi-I/O connector on the
rear panel (see
174
TAI: Temps Atomique International
GPS: The raw GPS time as transmitted by the GNSS satellites (as of
22-August-2023, this is currently 18 seconds ahead of UTC time).
If GPS or TAI time is used, then the proper timescale offsets must be set on
the MANAGEMENT/OTHER/Time Management page. (See
agement Screen" on page 186
and read the System Time). Local timescale allows a Local Clock to apply a
time offset for Time Zone and DST correction.
A
Local Clock
This option will appear under the name of the local clock you have set
up. See for more information. Local timescale allows a Local Clock to
apply a time offset for Time Zone and DST correction.
The incoming input time information may be provided as local time,
but System Time may be configured as UTC time, so internal com-
putations need to be performed. With the Timescale field set to
"Local", select the name of a previously created Local Clock. The Time
Zone and DST rules, as configured in the Local Clock will be applied
to the front panel time display. See for more information on Local
Clocks.
Baud
Rate: Determines the speed at which the output port will operate.
Data
Bits: Defines the number of Data Bits for the output port.
Parity: Configures the parity checking of the output port.
Stop
Bits: Defines the number of Stop Bits for the output.
page 363.
"Configurable Connectors" on
Note:
The fields viewable will depend on the selection for the Output
Mode.
Output
Mode:
Direct Output Value: Output will be low or high, determined by the
Output Value section below.
for more information on how to configure
can be set up through the
page 157).
CHAPTER
"The Time Man-
Time Management
"Viewing Input/Output Con-
2
SecureSync 2400 User Manual Rev. 5.2
page:

Advertisement

Table of Contents
loading

Table of Contents