Safran SecureSync 2400 User Manual page 74

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

2.9  Connecting Supply Power
58
The Rear View panel of the Hot Swap page will display a rendering of the
rear panel. You can hover over a power supply to confirm the bay number,
and power specifications.
The Hot Swap Status panels for Bay 1 and Bay 2 each provide information
and charts related to monitoring the power supplies of the unit, and contain
the following elements:
Health: OK, Warning, Fault, or Monitoring Disabled
Present: Installed or Not Installed
Monitoring: ON/OFF. Monitoring of Hot Swap Power Supply statuses
can be disabled to reduce logging and health status updates. This
setting disables alarming in the case of power supply failure or issue
(it is still possible to view statistics for the bay if monitoring is dis-
abled).
Note:
you choose to remove a power supply long term or keep
one inserted that you know is faulty. Disabling monitoring
on a faulty supply or empty bay will cause the overall
status to display as Okay (provided there is one fully func-
tional power supply installed).
Power
Type: AC 110/220 V, DC 12/24 V, or DC 24/48 V
Voltage
(V)
It is recommended to disable monitoring on a bay if
CHAPTER
2
SecureSync 2400 User Manual Rev. 5.2