Status Monitoring Via The Web Ui - Safran SecureSync 2400 User Manual

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

The INPUTS
their priority under the MONITORING submenu.
The TIMING
MONITORING submenu.
The NETWORK
MONITORING submenu. Toggle between eth0 and eth1 to view the traffic data
for each port.
The ALARMS
and alarms.
4.5.1.2

Status Monitoring via the Web UI

status information can be accessed via the SecureSync Web UI, such as:
The HOME screen provides time server status information, while the TOOLS >
System Monitor screen also displays hardware status data, e.g. temperature
curves:
Status Monitoring via the HOME Screen
The HOME screen of the SecureSync Web UI provides a system status overview
(see also
The HOME screen is divided into
CHAPTER
4
SecureSync 2400 User Manual Rev. 5.2
Menu provides monitoring of the references and the order of
Menu provides a description of the current oscillator state in the
Menu provides a graph of the network traffic in the
Menu provides valuable information about any current alerts
the STATUS submenu will list active alarms. Toggle between minor alarms
and major alarms to see each list.
the MONITORING submenu lists the temperature status, the memory, CPU,
and disk used thus far within the unit. Select each of these values to see a
graph relating to the measurement.
Time synchronization status, including references
GNSS satellites currently being tracked
NTP sync status and current Stratum level
Estimated time errors
Oscillator disciplining
Temperature monitoring
"The Web UI HOME Screen" on
page 34).
four
panels:
4.5  Quality Management
303

Advertisement

Table of Contents
loading

Table of Contents