Time Code Option Cards; Irig Out [1204-15, -1E, -22] - Safran SecureSync 2400 User Manual

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

APPENDIX
5.2.5

Time Code Option Cards

This section contains technical information and SecureSync Web UI procedures
for option cards designed to deliver timing data in time code formats, e.g. IRIG,
HAVE QUICK, or STANAG.
5.2.5.1

IRIG Out [1204-15, -1E, -22]

These IRIG Output option cards provide SecureSync with four IRIG outputs. Avail-
able with BNC connectors, Fiber Optic ST connectors, or RS-485 terminal block.
IRIG Out (BNC): Specifications
Figure 5-38:
432
E1 SSM
Value: This option selects the SSM quality level transmitted when
SSM is enabled.
Inputs/Outputs: (4) IRIG Outputs
Output
Signal: IRIG A, B, E, G, or NASA-36, amplitude modulated sine wave
(AM), 0.5V to 6V
into 50 Ω; or pulse-width-coded (DCLS).User-select-
p-p
able.
AM
Carrier: IRIG B 1000 Hz, IRIG A and G 100 or 100
AM Signal
Level: 500 mV to 10 V
DCLS Signal
Level: >10 kΩ TTL
Connector: AM and DCLS: BNC female
Accuracy: see
"IRIG Output Accuracy Specifications" on page 604
Number of
Cards: Up to 6
Ordering
Information: 1204-15, IRIG module, BNC Connector
Model 1204-15 option card rear plate
[high Z]; (modulated 2:1 to 6:1).
p-p
SecureSync 2400 User Manual

Advertisement

Table of Contents
loading

Table of Contents